Buy Schneider MCB 3 Pole Online – Schneider 3P MCB Full Range

Looking to buy Schneider MCB 3 Pole online? ElectriHub is your authorised source for the complete Schneider 3 Pole MCB range — the standard circuit breaker configuration for three-phase three-wire (3P) installations where simultaneous switching and short-circuit protection of all three phase conductors is required in a single compact DIN rail device. The Schneider 3P MCB — available across the Acti9 iC60N, iC60H, and iC60L series in current ratings from 1A through 63A with B, C, and D curves — is specified for three-phase motor feeders, three-phase sub-main circuits, TN-C-S incomer protection, three-phase distribution board outgoing circuits, and any balanced three-phase load application where only the three phase conductors require switching and overcurrent protection. Trusted globally for its precision trip accuracy, compact 54mm-wide (3 × 18mm) DIN rail footprint, high breaking capacity options up to 25kA, and full Acti9 modular accessory compatibility. Shop genuine Schneider 3 Pole MCB products with worldwide shipping, competitive pricing, and expert technical support — only at ElectriHub.

✓ Full 3P MCB Range

Acti9 iC60N, iC60H & iC60L — current ratings 1A to 63A in B, C and D curves at 6kA, 10kA, 15kA and 25kA

✓ 100% Genuine Products

Authentic Schneider Electric 3-pole MCBs with manufacturer warranty and BIS certification

✓ Worldwide Shipping

Fast delivery with complete export documentation for global projects

✓ Technical Support

Expert guidance for 3P MCB selection, trip curve choice, breaking capacity, and three-phase system design

Shop Schneider 3 Pole MCB by Series and Current Rating

Schneider Acti9 iC60N 3 Pole MCB
6kA | 1A – 63A | B / C / D Curve

Schneider Acti9 iC60N 3 Pole MCB

The Schneider Acti9 iC60N 3 Pole MCB is the flagship three-pole circuit breaker in the Schneider Acti9 range — rated 6kA breaking capacity at 230/400V AC and available in current ratings from 1A through 63A with B, C, and D curve options. The 3-pole configuration provides simultaneous switching and overcurrent protection of all three phase conductors in a single compact 54mm-wide (3 × 18mm) DIN rail module. Dual-rated under IEC 60898-1 and IEC 60947-2 — suitable for both residential consumer units and industrial-classified switchgear assemblies. Full Acti9 snap-on accessory compatibility: iOF auxiliary contact, iSD shunt release, iMN undervoltage release, and rotary handle kit. The most widely specified Schneider 3P MCB for three-phase three-wire final circuit and sub-main protection in commercial and light industrial distribution boards across India and the Middle East.

View Products
Schneider Acti9 iC60H 3 Pole MCB
10kA | 1A – 63A | B / C / D Curve

Schneider Acti9 iC60H 3 Pole MCB

The Schneider Acti9 iC60H 3 Pole MCB delivers 10kA breaking capacity — the mandatory specification for three-phase incomer and sub-main protection in commercial offices, retail complexes, hospitals, data centres, and industrial panels where the prospective fault current at the distribution board exceeds 6kA. Available across the full current rating range from 1A to 63A with B, C, and D curves. Rated exclusively under IEC 60947-2 — the correct standard for industrial-classified switchgear assemblies and all commercial distribution boards where PSCC verification confirms fault levels above 6kA. Full Acti9 accessory compatibility. The standard Schneider 3P MCB specification for incomer and sub-main circuit breakers in most commercial building distribution boards in India and the Middle East.

View Products
Schneider Acti9 iC60L 3 Pole MCB
15kA – 25kA | 1A – 63A | C / D Curve

Schneider Acti9 iC60L 3 Pole MCB

The Schneider Acti9 iC60L 3 Pole MCB is the high breaking capacity three-pole variant — available at 15kA and 25kA — for incomer and sub-main protection in industrial main distribution boards, large commercial buildings, data centre PDUs, and critical infrastructure panels fed from large HV/LV transformers or main LV bus sections where prospective fault currents exceed 10kA at the distribution board incomer level. Available from 1A to 63A with C and D curves. Rated under IEC 60947-2. The iC60L 3-pole at 25kA is the standard specification for three-phase incomer MCBs in high-integrity industrial and utility-scale switchgear assemblies and critical facility main distribution boards.

View Products
Schneider 3 Pole MCB 6A to 32A
6A – 32A | Three-Phase Final Circuits

Schneider 3P MCB – 6A to 32A Range

The Schneider 3 Pole MCB in the 6A to 32A current rating range covers three-phase final circuit protection for balanced three-phase loads in commercial and light industrial installations: three-phase heating elements, three-phase packaged HVAC units, three-phase motor feeders, and three-phase welding supply circuits. The most commonly ordered ratings in this range are the Schneider 3P MCB 6A for instrumentation and control circuits, 3P MCB 10A for small three-phase heating loads, 3P MCB 16A for three-phase balanced lighting and socket circuits, 3P MCB 20A for dedicated HVAC and FCU circuits, and 3P MCB 32A for three-phase motor feeder and EV charging point supply circuits.

View Products
Schneider 3 Pole MCB 40A to 63A
40A – 63A | Sub-Main & Incomer

Schneider 3P MCB – 40A to 63A Range

The Schneider 3 Pole MCB in the 40A to 63A range is principally specified for three-phase incomer and sub-main circuit protection in commercial distribution boards and light industrial panels. The Schneider 3P MCB 40A is the standard sub-main feeder specification for smaller three-phase distribution sections and motor control panels. The Schneider 3P MCB 50A covers sub-main circuits for medium-load commercial floors and large HVAC compressor supply circuits. The Schneider 3P MCB 63A is the maximum rating in the Acti9 MCB range and is used as the incomer for small three-phase distribution boards and as a sub-main feeder where load calculations dictate a 63A protective device — beyond which a Schneider Compact NSX MCCB is the appropriate solution.

View Products
Schneider 3 Pole MCB D Curve
D Curve | Motor & Transformer Feeders

Schneider 3P MCB – D Curve Range

The Schneider 3 Pole MCB D Curve — available in iC60N (A9F5X3XX) and iC60H (A9F9X3XX) across ratings from 1A to 63A — is specified for three-phase motor feeder circuits, transformer primary protection circuits, and solenoid or inductive load circuits where DOL start-up inrush current would nuisance-trip a C curve 3-pole MCB. The D curve instantaneous trip at 10–20× In provides the widest inrush tolerance in the standard MCB range. The Schneider 3P MCB D Curve is the standard specification for three-phase motor feeders in industrial panels and motor control centres (MCCs) — covering direct-on-line (DOL) motors from fractional kW up to approximately 15kW at 63A, depending on the motor starting current profile and cable sizing.

View Products

Schneider MCB 3 Pole – Full Model Specifications

Series Current Rating Curve Model Reference (3P) Breaking Capacity (Icu) Voltage Rating Standard
Acti9 iC60N 1A / 2A / 3A / 4A / 6A / 10A / 16A / 20A / 25A / 32A / 40A / 50A / 63A C A9F743XX (e.g. A9F74363 for 63A) 6kA @ 230/400V AC 230/400V AC IEC 60898-1 / IEC 60947-2
Acti9 iC60N 1A – 63A (full range) B A9F443XX 6kA @ 230/400V AC 230/400V AC IEC 60898-1 / IEC 60947-2
Acti9 iC60N 1A – 63A (full range) D A9F543XX 6kA @ 230/400V AC 230/400V AC IEC 60947-2
Acti9 iC60H 1A – 63A (full range) C A9F843XX 10kA @ 230/400V AC 230/400V AC IEC 60947-2
Acti9 iC60H 1A – 63A (full range) B A9F643XX 10kA @ 230/400V AC 230/400V AC IEC 60947-2
Acti9 iC60H 1A – 63A (full range) D A9F943XX 10kA @ 230/400V AC 230/400V AC IEC 60947-2
Acti9 iC60L 1A – 63A (full range) C A9F153XX 15kA @ 230/400V AC 230/400V AC IEC 60947-2
Acti9 iC60L 1A – 63A (full range) C / D A9F073XX 25kA @ 230/400V AC 230/400V AC IEC 60947-2

Part number key: A9F[curve digit][poles digit][rating] — Poles digit for 3-pole = 3. Curve digit: 7 = C curve (iC60N), 4 = B curve (iC60N), 5 = D curve (iC60N), 8 = C curve (iC60H), 6 = B curve (iC60H), 9 = D curve (iC60H). Rating is a 2-digit suffix, e.g. 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A. Example: A9F74316 = Acti9 iC60N, C curve, 3-pole, 16A. Contact ElectriHub to verify the exact part number for your required rating before ordering.

Schneider 3P MCB – Most Ordered Ratings Quick Reference

Current Rating Typical Application Recommended Curve iC60N 3P Part No. (C Curve) iC60H 3P Part No. (C Curve)
6A Three-phase control circuit and instrumentation supply C or B A9F74306 A9F84306
10A Three-phase small heating load and lighting transformer supply C A9F74310 A9F84310
16A Three-phase balanced circuits, small motor feeders (2.2kW DOL) C A9F74316 A9F84316
20A Three-phase HVAC FCU, small three-phase heating, welding supply C or D A9F74320 A9F84320
25A Three-phase motor feeder (5.5kW DOL), EV charging supply C or D A9F74325 A9F84325
32A Three-phase motor feeder (7.5kW DOL), commercial sub-circuit C or D A9F74332 A9F84332
40A Three-phase sub-main feeder, MCC incomer, large HVAC supply C A9F74340 A9F84340
50A Three-phase sub-main, medium commercial floor feeder, large motor supply C A9F74350 A9F84350
63A Three-phase distribution board incomer, maximum Acti9 MCB rating C A9F74363 A9F84363

Schneider 3 Pole MCB Accessories – Selection Guide

Accessory Part Reference Compatible Series Function
Auxiliary Contact (iOF) A9A26924 / A9A26925 Acti9 iC60N / iC60H / iC60L (all poles) Snap-on OF auxiliary contact — provides remote volt-free indication of 3P MCB ON/OFF/tripped status to BMS, SCADA, or PLC digital input. Essential for monitored three-phase incomer and sub-main circuits in smart buildings, motor control centres, and generator panels
Shunt Release (iSD) A9A26482 (230V AC) / A9A26486 (24V DC) Acti9 iC60N / iC60H / iC60L (all poles) Remote trip coil — allows the 3P MCB to be tripped remotely from a fire alarm panel, BMS emergency output, generator control panel, or load shedding controller. Used in three-phase sub-main circuit breakers and motor feeder MCBs where remote de-energisation on fault or emergency is a system requirement
Undervoltage Release (iMN) A9A26470 (230V AC) / A9A26474 (24V DC) Acti9 iC60N / iC60H / iC60L (all poles) Automatic trip on supply undervoltage or total supply loss — prevents automatic reconnection of three-phase circuits on voltage restoration. Used in generator panel incomers and motor feeder MCBs where an uncontrolled auto-reconnect after a power outage could damage connected three-phase equipment or create a safety hazard
Rotary Handle Kit A9A26510 (black) / A9A26513 (red-yellow lockable) Acti9 iC60N / iC60H / iC60L (all poles) Panel door rotary handle for external 3P MCB operation without opening the enclosure — the lockable padlock variant is the standard LOTO (Lockout/Tagout) isolation device for three-phase distribution board incomers and sub-main circuit breakers. Required on any 3P MCB that serves as the main isolation point for a distribution board or section of three-phase installation
Comb Busbar (3P) A9XPC312 (3P, 12-way) Acti9 iC60N / iC60H / iC60L Three-pole phase-distributed comb busbar for three-phase distribution boards — simultaneously connects all three phases to the 3P incomer MCB and all outgoing three-phase circuit breakers. Eliminates individual feed wires and simplifies board assembly in three-phase distribution panels and motor control centres
Terminal Shield (3P) A9XPH306 Acti9 iC60 Series (3-pole) IP20 touch-protection terminal covers for three-pole MCB top and bottom cable entry — required for finger-safe IP compliance in distribution boards accessible to non-skilled persons and for compliance with switchgear assembly IP requirements in industrial panels
Padlock Accessory A9A26933 Acti9 iC60 Series (all poles) Padlock attachment for rotary handle — allows a standard padlock to be fitted to the rotary handle of the 3P MCB for LOTO isolation. Accepts padlocks with shackle diameter up to 8mm. Essential for safe maintenance isolation of three-phase distribution board incomers and motor feeder MCBs under LOTO procedures
DIN Rail Enclosure (3-Phase) NSYPLM / Pragma iC60 Three-Phase Series All Schneider Acti9 MCB Series Three-phase DIN rail enclosures for surface and flush mounting — designed to accept a 3P Acti9 MCB as the incomer with downstream outgoing circuit breakers on a common 3P comb busbar. Available in 4-way to 36-way configurations for commercial floors and light industrial panels
Need Help With Your Schneider 3 Pole MCB Selection?

Contact Our Technical Team

Not sure which current rating, curve type, or breaking capacity to specify for your Schneider 3P MCB application — or whether your installation requires a 3-pole MCB with iSD shunt release and iMN undervoltage release for generator or emergency trip functionality? Our engineers will help you select the correct Schneider 3 Pole MCB configuration, breaking capacity, and accessory fit-out for your specific system design and application.

Contact Now

Download Product Line Card

Browse our complete range of Schneider Electric MCBs — Acti9 iC60N, iC60H, and iC60L in 1-pole through 4-pole configurations across all current ratings from 1A to 63A — alongside RCCBs, MCCBs, isolators, and distribution board accessories with full specifications and ordering information for global projects.

Download Line Card

Company Profile

Learn more about ElectriHub — your global partner for genuine Schneider Electric circuit protection and switchgear products delivered with technical excellence and after-sales support worldwide.

Download Profile

What is a Schneider MCB 3 Pole?

A Schneider MCB 3 Pole (Miniature Circuit Breaker, 3-pole) is a DIN rail mounted protective device that simultaneously switches and protects all three phase conductors (L1, L2, L3) of a three-phase electrical installation in a single compact operation. The Schneider 3P MCB is the standard circuit breaker configuration for three-phase circuits where only the phase conductors require overcurrent protection and switching — including three-phase motor feeders, three-phase sub-main circuits, three-phase distribution board outgoing circuits, and TN-C-S system incomers where the neutral must remain solidly bonded and must not be switched. The Schneider 3 Pole MCB is available in the Acti9 iC60N (6kA), iC60H (10kA), and iC60L (15kA–25kA) series across current ratings from 1A through 63A with B, C, and D trip curves. When you buy Schneider MCB 3 Pole from ElectriHub, you receive 100% genuine Schneider Electric products with manufacturer warranty, BIS certification, and full pre-sales technical support.

When Do You Need a Schneider 3 Pole MCB? — The Key Applications

The Schneider 3 Pole MCB is the standard specification for the vast majority of three-phase circuit protection applications in Indian commercial and industrial installations. The following are the primary applications where a 3P MCB is the correct specification:

  • Three-Phase Motor Feeders (TN-C-S Systems): The most common application for a Schneider 3P MCB in Indian commercial and industrial installations is short-circuit and overload protection for three-phase motor feeder circuits. A 3-pole MCB in C or D curve protects the motor supply cable against short-circuit faults on all three phases simultaneously. For DOL motor starting applications with high inrush currents, a D curve 3P MCB is specified to prevent nuisance tripping during motor acceleration. For VFD-fed motors, a C curve 3P MCB is standard as the short-circuit protective device upstream of the drive
  • TN-C-S System Distribution Board Incomers: In India, most urban commercial and industrial premises are supplied under a TN-C-S (or equivalent combined PEN conductor) earthing arrangement from the electricity distribution company. Under TN-C-S, the neutral must NOT be switched — it must remain bonded to earth at the main earthing terminal at all times. A Schneider 3 Pole MCB is the correct incomer specification for distribution boards on TN-C-S supplies, providing simultaneous switching and protection of all three phase conductors while leaving the neutral permanently connected and bonded
  • Three-Phase Sub-Main Circuits: Three-phase sub-main feeders from a main distribution board to secondary distribution boards, motor control centres (MCCs), or large three-phase load groups are routinely protected by a Schneider 3P MCB — sized to the sub-main cable rating and load current, and selected for breaking capacity matched to the verified PSCC at the main distribution board busbar. The 3P configuration is correct for three-wire sub-main feeders and for any sub-main where the neutral is not carried in the feeder cable (e.g., three-wire three-phase balanced industrial sub-mains)
  • Three-Phase HVAC and Chiller Plant Supply: Large commercial HVAC plant — including chiller units, air handling units (AHUs), cooling tower fans, and packaged roof-top units — typically draws balanced three-phase current with no neutral requirement at the load terminals. A Schneider 3P MCB in C curve (or D curve for compressor circuits with high starting current) is the standard protective device for three-phase HVAC supply circuits from the building services distribution board
  • Three-Phase Welding and Industrial Process Equipment: Industrial welding machines, resistance heating elements, three-phase furnace loads, and process equipment drawing balanced three-phase current are protected by a Schneider 3P MCB selected for the equipment's rated current and starting characteristics. D curve 3P MCBs are commonly specified for welding supply circuits where initial inrush transients could cause nuisance tripping of C curve devices
  • Motor Control Centre (MCC) Outgoing Feeders: In motor control centres serving industrial plant, each outgoing motor feeder is individually protected by a Schneider 3P MCB — typically in D curve at the rating matching the motor DOL starting current and cable ampacity. The 3P MCB provides short-circuit protection for the motor starter and supply cable; a separate overload relay or motor protection relay in the starter provides overload protection for the motor windings. At ratings up to 63A, the Acti9 iC60H 3P D Curve is the standard MCC outgoing feeder MCB specification for motors up to approximately 15kW DOL at 400V
  • Three-Phase EV Charging Infrastructure (Three-Wire): Three-phase AC EV chargers on installations where only a three-wire (no neutral) supply is provided to the charger — or where the charger's internal design does not require a neutral at the supply terminals — are protected by a Schneider 3P MCB at the appropriate current rating. For three-phase 11kW chargers drawing up to 16A per phase, a 3P MCB 20A or 25A C curve is typically specified. Always verify the EV charger's supply terminal requirements (3P or 3P+N) before specifying 3-pole vs 4-pole
  • International Export Projects (Three-Wire Circuits): On international EPC and export projects, Schneider 3P MCB devices are specified for all three-phase three-wire circuit protection applications — motor feeders, balanced heating loads, three-wire sub-mains, and outgoing circuits from three-phase distribution boards where no neutral is required at the load. The Acti9 iC60N and iC60H 3-pole range complies with IEC 60898-1 and IEC 60947-2 and is accepted on projects in Europe, the Middle East, Southeast Asia, and Africa

Schneider 3P MCB vs 4P MCB — When to Use Each

A common specification question is whether a Schneider 3 Pole MCB is sufficient or whether a 4-pole MCB is required. The distinction depends on the earthing system and whether neutral isolation is required:

  • Use a Schneider 3 Pole MCB when: The installation uses a TN-C-S (PME) earthing system where the neutral and earth are combined in the supply cable (PEN conductor) up to the point of entry, and the neutral is solidly bonded to earth at the main earthing terminal of the distribution board. In TN-C-S systems — which apply to most urban commercial and industrial premises in India supplied by the local distribution company — the neutral must NOT be switched. A Schneider 3P MCB is the correct and standard specification for TN-C-S system incomers, sub-main feeders, and all three-phase circuit protection where neutral switching is neither required nor permitted. Also correct for all three-phase three-wire (no neutral) circuits regardless of earthing system
  • Use a 4-pole MCB when: The installation uses a TN-S or TT earthing system where the neutral and protective earth are separate conductors throughout, and neutral isolation is required at the incomer for safe maintenance isolation. Also required for generator and ATS panels where the generator has its own neutral-earth bond, and for international export projects under local regulations that mandate neutral switching at distribution board incomers
  • Always verify with your electrical engineer: The correct pole configuration for a distribution board incomer MCB must be determined by a qualified electrical engineer based on a verified assessment of the earthing system type, supply characteristics, and applicable wiring regulation. ElectriHub's technical team can provide guidance on earthing system identification and 3-pole vs 4-pole MCB selection for your specific project

Schneider 3P MCB Part Number Guide

The Schneider 3 Pole MCB part number follows the standard Acti9 format: A9F[curve digit]3[rating] — where the poles digit is always 3 for three-pole devices. The curve digit: 7 = C curve (iC60N), 4 = B curve (iC60N), 5 = D curve (iC60N), 8 = C curve (iC60H), 6 = B curve (iC60H), 9 = D curve (iC60H). The rating suffix is a 2-digit code: 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A. For example: A9F74316 = Acti9 iC60N, C curve, 3-pole, 16A (6kA). A9F84340 = Acti9 iC60H, C curve, 3-pole, 40A (10kA). A9F54332 = Acti9 iC60N, D curve, 3-pole, 32A (6kA). For iC60L 3-pole at 25kA: A9F07363 = Acti9 iC60L, 3-pole, 63A, 25kA. Always verify the complete part number with ElectriHub's technical team before ordering, particularly for high-breaking-capacity and D curve specifications.

Schneider 3P MCB — Choosing the Right Breaking Capacity

Selecting the correct breaking capacity for a Schneider 3 Pole MCB requires a verified prospective short-circuit current (PSCC) calculation at the point of installation:

  • 6kA (Acti9 iC60N 3P): Appropriate for three-phase final circuit and sub-main protection at locations remote from the supply source, where cable impedance limits the PSCC at the MCB terminals to at or below 6kA. Suitable for small commercial buildings, residential premises, and industrial sub-circuit protection at the end of long cable runs. Never assume 6kA is adequate for a distribution board incomer without a verified PSCC calculation — particularly in urban Indian commercial and industrial premises where utility fault levels are high
  • 10kA (Acti9 iC60H 3P): The standard safe-default specification for Schneider 3 Pole MCB applications in commercial buildings, industrial premises, and multi-storey residential blocks in Indian cities. The iC60H 3P at 10kA covers the great majority of commercial and light industrial distribution board locations and motor control centres where PSCC has been calculated between 6kA and 10kA. This is the recommended specification for any three-phase MCB application where PSCC has not been formally calculated, accepting the modest additional cost of the iC60H over the iC60N in exchange for a higher protection margin
  • 15kA–25kA (Acti9 iC60L 3P): Required for main distribution board incomers and sub-main circuit breakers in large commercial buildings, industrial facilities, and critical infrastructure installed close to the HV/LV transformer or main LV switchboard where PSCC calculations show fault levels above 10kA. At 25kA, the iC60L 3P is the maximum breaking capacity available in the Acti9 MCB range — beyond which Schneider Compact NSX or Masterpact MCCBs and ACBs are specified

Schneider 3P MCB Curve Selection — B, C, and D Curve Guide

Trip curve selection for a Schneider 3 Pole MCB is determined by the inrush or starting current characteristics of the connected load:

  • B Curve (3–5× In instantaneous trip): The Schneider 3P MCB B Curve is specified for three-phase resistive loads, lighting circuits, and sensitive electronic equipment where overcurrent protection must operate at the lowest possible multiple of rated current to protect the load. Also specified for three-phase circuits in installations with low available fault current where a higher-sensitivity trip threshold is required. Less commonly used than C curve for general three-phase circuit protection
  • C Curve (5–10× In instantaneous trip): The Schneider 3P MCB C Curve is the standard specification for the vast majority of three-phase circuit protection applications — three-phase sub-main feeders, balanced three-phase loads, HVAC supply circuits, and motor feeders where the motor starting current does not exceed 10× In. The C curve iC60N and iC60H 3P are the highest-volume Schneider 3 Pole MCB variants ordered for commercial and light industrial projects
  • D Curve (10–20× In instantaneous trip): The Schneider 3P MCB D Curve is specified for three-phase motor feeders with high DOL starting currents, transformer primary protection circuits, and solenoid or inductive load circuits where the starting inrush current exceeds 10× the MCB rated current and would cause nuisance tripping of a C curve device. D curve 3P MCBs are the standard short-circuit protective device for direct-on-line motor starters in industrial MCC panels and motor feeder circuits where the motor starting current profile dictates a higher instantaneous trip threshold

Buy Schneider MCB 3 Pole Online from ElectriHub

ElectriHub is your trusted one-stop platform to buy Schneider 3 Pole MCB online — across the complete Acti9 iC60N, iC60H, and iC60L series in every current rating from 1A through 63A, in B, C, and D curves, at 6kA, 10kA, 15kA, and 25kA breaking capacities, along with the full Acti9 accessory range including iOF auxiliary contacts, iSD shunt releases, iMN undervoltage releases, rotary handles, padlock kits, 3-pole comb busbars, and three-pole terminal shields. We supply 100% genuine Schneider Electric products with manufacturer warranty, competitive pricing for single units and bulk project orders, fast worldwide shipping with export documentation, and free pre-sales technical support from qualified electrical engineers. Whether you are specifying a Schneider 3P MCB 63A iC60H as the incomer for a commercial distribution board, a Schneider 3P MCB 32A D Curve for a three-phase motor feeder in an MCC, or a range of 3-pole MCBs across all ratings for a complete industrial panel build — ElectriHub is your preferred source for Schneider 3 Pole MCB online.

Why Buy Schneider 3P MCB from ElectriHub?

  • ✓ Complete Schneider 3 Pole MCB range — Acti9 iC60N, iC60H, and iC60L in every current rating from 1A to 63A
  • ✓ All curve types available — B, C, and D curve in 6kA, 10kA, 15kA, and 25kA breaking capacities
  • ✓ Full Acti9 accessory range — iOF auxiliary contacts, iSD shunt releases, iMN undervoltage releases, rotary handles, and padlock kits
  • ✓ 3-pole comb busbars and three-pole terminal shields available for complete switchboard assembly
  • ✓ 100% genuine Schneider Electric products with IEC 60898-1 / IEC 60947-2 certification and manufacturer warranty
  • ✓ BIS-certified products available for Indian market compliance
  • ✓ Competitive pricing with volume discounts for panel builders, EPC contractors, and switchgear manufacturers
  • ✓ Complete distribution board MCB sets — matched by load schedule and motor schedule on request
  • ✓ Worldwide shipping with full tracking and export documentation
  • ✓ Technical pre-sales support — 3P vs 4P guidance, breaking capacity verification, curve selection, and MCC/motor feeder MCB sizing
  • ✓ Fast dispatch from our global warehouse — urgent orders dispatched same or next business day
  • ✓ Dedicated account managers for EPC firms, panel builders, switchgear manufacturers, and project orders

Frequently Asked Questions

Q: What is the most commonly ordered Schneider 3 Pole MCB in India?

The highest-volume Schneider 3 Pole MCB ordered through ElectriHub for Indian projects is the Acti9 iC60H 3-pole C Curve 32A (A9F84332) and iC60H 3-pole C Curve 63A (A9F84363) — used for three-phase sub-main feeders, motor feeder protection in commercial distribution boards, and incomer protection in small three-phase panels. For industrial MCC applications, the iC60H 3P D Curve in ratings from 16A to 63A is the most ordered variant for direct-on-line motor feeder protection. Contact ElectriHub to confirm stock availability and lead times for your required rating and breaking capacity.

Q: Do I need a 3 Pole MCB or a 4 Pole MCB for my three-phase distribution board in India?

In India, the majority of urban commercial and industrial premises are supplied under a TN-C-S (or equivalent combined PEN conductor) earthing arrangement from the electricity distribution company. Under TN-C-S, the neutral must NOT be switched at the distribution board incomer — a Schneider 3 Pole MCB is the correct incomer specification. However, if the installation uses a TN-S earthing system (with a separate neutral and earth throughout, confirmed by the supply authority or by an electrical engineer's assessment of the supply characteristics), a 4-pole MCB is required at the incomer. For generator and ATS panels, 4-pole switching is always required regardless of the utility earthing system. Always have your earthing system confirmed by a qualified electrical engineer before specifying 3-pole or 4-pole at the incomer.

Q: What is the difference between Schneider iC60N 3P and iC60H 3P?

The Acti9 iC60N 3-pole MCB is rated at 6kA breaking capacity and is dual-rated under IEC 60898-1 and IEC 60947-2. The Acti9 iC60H 3-pole MCB is rated at 10kA and is rated under IEC 60947-2 only. Both are available across the same current rating range (1A–63A) and curve options (B, C, D) and share the same Acti9 accessory system. For any commercial distribution board incomer or sub-main application where the PSCC has not been formally verified, the iC60H 3P at 10kA is the safer default specification. The iC60N 3P is appropriate only where a PSCC calculation or measurement confirms the fault level at the MCB terminals is at or below 6kA.

Q: Which Schneider 3P MCB should I specify for a direct-on-line motor feeder?

For a direct-on-line (DOL) motor feeder, the standard Schneider 3 Pole MCB specification is the Acti9 iC60H 3P D Curve at the current rating matching your motor cable ampacity (not the motor FLC — the MCB protects the cable, not the motor windings, which are protected by the overload relay in the DOL starter). The D curve is specified over the C curve because DOL motor starting currents of 6–8× FLC would approach or exceed the C curve instantaneous trip threshold (5–10× In) and risk nuisance tripping during every motor start. The iC60H is specified over the iC60N for the additional breaking capacity margin. Contact ElectriHub's technical team with your motor kW rating and supply voltage for a complete DOL starter MCB and contactor specification.

Q: Can I use a Schneider 3P MCB as the incomer for a three-phase distribution board?

Yes — a Schneider 3 Pole MCB is the correct and standard incomer device for a three-phase distribution board supplied under a TN-C-S earthing system, which applies to most urban commercial and industrial premises in India. The 3P incomer MCB is sized to the distribution board's maximum demand current and selected for the breaking capacity matching the verified PSCC at the distribution board incomer terminals. A rotary handle kit (A9A26513 lockable variant) should be fitted to the incomer 3P MCB to allow external operation and LOTO isolation without opening the distribution board enclosure.

Q: Do you ship Schneider MCB 3 Pole internationally?

Yes. ElectriHub ships Schneider MCB 3 Pole products — all series, current ratings, curve types, and breaking capacities — to customers worldwide. We provide complete export documentation including commercial invoices, packing lists, certificates of origin, and MSDS where required. Contact our team with your Schneider 3P MCB part number (e.g., A9F84340, A9F74316, or A9F07363), quantity, and delivery destination for a fast shipping quotation and lead time confirmation.

Order Your Schneider MCB 3 Pole Today

Ready to buy Schneider 3 Pole MCB online? Browse our complete range above — Acti9 iC60N, iC60H, and iC60L in every current rating from 1A to 63A, across all curve types and breaking capacities — along with matching iOF auxiliary contacts, iSD shunt releases, iMN undervoltage releases, rotary handles, padlock kits, 3-pole comb busbars, and DIN rail enclosures for three-phase panel assembly. Contact our technical team for 3P MCB selection support, 3-pole vs 4-pole guidance based on your earthing system, breaking capacity verification, curve selection for motor feeder applications, and complete distribution board BOM for three-phase projects of any scale. ElectriHub ships genuine Schneider 3 Pole MCB worldwide and supports projects of all sizes — from a single replacement 3P incomer MCB to complete MCC panel and distribution board builds for large commercial and industrial projects. Get 100% authentic Schneider 3P MCBs with fast dispatch, competitive pricing, and full technical support — only at ElectriHub.