Buy Schneider MCB 16 Amp Online – Schneider 16A MCB Full Range
✓ Full 16A MCB Range
Acti9 iC60N, iC60H, iC60L, Easy9 & Domae — 1P, 2P, 3P & 4P in B, C and D curve variants
✓ 100% Genuine Products
Authentic Schneider Electric MCBs with manufacturer warranty and BIS certification
✓ Worldwide Shipping
Fast delivery with complete export documentation
✓ Technical Support
Expert guidance for 16A MCB selection, curve type, breaking capacity, and RCBO combinations
Shop Schneider 16A MCB by Series
Schneider Acti9 iC60N 16A MCB
The Schneider Acti9 iC60N 16A MCB is the flagship 16A circuit breaker in the Schneider range — rated 6kA breaking capacity at 230/400V AC and available in 1-pole, 2-pole, 3-pole, and 4-pole configurations with B and C curve options. Compact 18mm per pole DIN rail mounting with the full Acti9 snap-on accessory system: iOF auxiliary contact, iSD shunt release, iMN undervoltage release, and rotary handle kit. Dual-rated under IEC 60898-1 and IEC 60947-2 — suitable for both residential consumer units and industrial-classified switchgear assemblies. The most specified Schneider 16A MCB globally for lighting, socket, and dedicated appliance circuits.
View Products
Schneider Acti9 iC60H 16A MCB
The Schneider Acti9 iC60H 16A MCB delivers 10kA breaking capacity — the correct specification for final circuit protection in commercial offices, retail, hospitality, and light industrial panels where the prospective fault current at the distribution board has been calculated above 6kA. Available in 1P, 2P, 3P, and 4P with B, C, and D curves. Full Acti9 accessory compatibility. Rated exclusively under IEC 60947-2, making the iC60H 16A the mandatory specification for outgoing circuit breakers in industrial-classified switchgear assemblies. Widely used for lighting and socket circuits in commercial distribution boards close to the HV/LV substation.
View Products
Schneider Acti9 iC60L 16A MCB
The Schneider Acti9 iC60L 16A MCB is the high breaking capacity variant — available at 15kA and 25kA — for final circuit protection in industrial main distribution boards, data centre PDUs, and critical infrastructure panels fed from large transformers or bus sections where prospective fault currents exceed 10kA even at the outgoing circuit level. Available in 1P, 2P, 3P, and 4P with C and D curves. Rated under IEC 60947-2. The iC60L 16A at 25kA is the standard specification for outgoing MCBs in high-integrity industrial and utility-scale switchgear assemblies where maximum fault current withstand is the design requirement.
View Products
Schneider 16A MCB – B Curve
The Schneider 16A MCB B Curve — available in iC60N (A9F44116), iC60H (A9F64116), and Easy9 (EZ9F14116) — is specified for purely resistive or low-inrush load circuits where maximum cable protection sensitivity is required. The B curve instantaneous trip at 3–5× In (48A–80A) makes it ideal for LED lighting circuits, electric heater circuits, underfloor heating supplies, and instrumentation supply circuits in TT earthing systems where cable protection against high-impedance faults is the primary design concern. In European electrical installations, the B curve 16A MCB is the standard specification for all domestic socket and lighting circuits.
View ProductsSchneider MCB 16 Amp – Full Model Specifications
| Series | Model Reference | Poles | Curve | Breaking Capacity (Icu) | Voltage Rating | Standard |
|---|---|---|---|---|---|---|
| Acti9 iC60N | A9F74116 / A9F74216 / A9F74316 / A9F74416 | 1P / 2P / 3P / 4P | C | 6kA @ 230/400V AC | 230/400V AC | IEC 60898-1 / IEC 60947-2 |
| Acti9 iC60N | A9F44116 / A9F44216 / A9F44316 / A9F44416 | 1P / 2P / 3P / 4P | B | 6kA @ 230/400V AC | 230/400V AC | IEC 60898-1 / IEC 60947-2 |
| Acti9 iC60N | A9F54116 / A9F54216 / A9F54316 / A9F54416 | 1P / 2P / 3P / 4P | D | 6kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Acti9 iC60H | A9F84116 / A9F84216 / A9F84316 / A9F84416 | 1P / 2P / 3P / 4P | C | 10kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Acti9 iC60H | A9F64116 / A9F64216 / A9F64316 / A9F64416 | 1P / 2P / 3P / 4P | B | 10kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Acti9 iC60H | A9F94116 / A9F94216 / A9F94316 / A9F94416 | 1P / 2P / 3P / 4P | D | 10kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Acti9 iC60L | A9F15116 / A9F15216 / A9F15316 / A9F15416 | 1P / 2P / 3P / 4P | C | 15kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Acti9 iC60L | A9F07116 / A9F07216 / A9F07316 / A9F07416 | 1P / 2P / 3P / 4P | C / D | 25kA @ 230/400V AC | 230/400V AC | IEC 60947-2 |
| Easy9 | EZ9F34116 / EZ9F34216 / EZ9F34316 | 1P / 2P / 3P | C | 6kA @ 230/400V AC | 230/400V AC | IEC 60898-1 |
| Easy9 | EZ9F14116 / EZ9F14216 / EZ9F14316 | 1P / 2P / 3P | B | 6kA @ 230/400V AC | 230/400V AC | IEC 60898-1 |
| Domae | DOM06816 / DOM06816-2P | 1P / 2P | C | 6kA @ 230V AC | 230V AC | IEC 60898-1 |
Schneider MCB 16A Accessories – Selection Guide
| Accessory | Part Reference | Compatible Series | Function |
|---|---|---|---|
| Auxiliary Contact (iOF) | A9A26924 / A9A26925 | Acti9 iC60N / iC60H / iC60L | Snap-on OF auxiliary contact — provides remote volt-free indication of MCB ON/OFF/tripped status to BMS, SCADA, or PLC digital input. Essential for monitored outgoing circuits in smart buildings and automated distribution boards |
| Shunt Release (iSD) | A9A26482 (230V AC) / A9A26486 (24V DC) | Acti9 iC60N / iC60H / iC60L | Remote trip coil — allows individual 16A outgoing circuits to be tripped remotely from a fire alarm panel, BMS emergency output, or load shedding controller without physical access to the distribution board |
| Undervoltage Release (iMN) | A9A26470 (230V AC) / A9A26474 (24V DC) | Acti9 iC60N / iC60H / iC60L | Automatic trip on supply undervoltage or total loss — prevents automatic circuit reconnection on voltage restoration. Used on critical equipment supply circuits where uncontrolled re-energisation after a power outage could damage sensitive loads |
| Rotary Handle Kit | A9A26510 (black) / A9A26513 (red-yellow lockable) | Acti9 iC60N / iC60H / iC60L | Panel door rotary handle for external MCB operation without opening the enclosure — lockable padlock variant provides LOTO (Lockout/Tagout) capability for safe maintenance isolation of individual 16A circuits |
| Comb Busbar | A9XPC312 (3P) / A9XPH212 (2P, 12-way) | Acti9 iC60N / iC60H / iC60L / Easy9 | Phase-distributed comb busbar eliminating individual feed wires between incomer and outgoing MCBs — standard accessory for all distribution boards using Schneider 16A MCBs as outgoing circuit breakers |
| iC60 RCBO 16A | A9D11616 (1P+N, 30mA, C16) / A9D31616 (1P+N, 300mA, C16) | Acti9 Residual Current Range | Combined 16A MCB and residual current protection in a single 1P+N DIN rail module — replaces the MCB + RCCB combination for individual circuit earth leakage protection. 30mA for personal protection on socket and bathroom circuits; 300mA for fire protection on lighting circuits |
| Terminal Shield | A9XPH206 / A9XPH306 | Acti9 iC60 Series | IP20 touch-protection terminal covers for top and bottom cable entry — required for finger-safe IP compliance in consumer units and distribution boards accessible to non-skilled persons |
| DIN Rail Enclosure | NSYPLM / Pragma iC60 Series | All Schneider MCB Series | Surface-mounted and flush-mounted DIN rail enclosures compatible with Acti9, Easy9, and Domae 16A MCBs — available in single-phase and three-phase configurations for residential and commercial distribution boards |
Contact Our Technical Team
Not sure whether to specify a Schneider Easy9 16A MCB or Acti9 iC60N for your residential consumer unit — or whether your commercial panel requires iC60H at 10kA? Our engineers will help you select the correct 16A MCB series, curve type, and breaking capacity, along with the right RCBO or RCCB combination, comb busbar, and enclosure for your distribution board design.
Contact NowDownload Product Line Card
Browse our complete range of Schneider Electric MCBs — Acti9, Easy9, Domae, and iC60 series across all current ratings from 6A to 63A — alongside RCBOs, RCCBs, MCCBs, isolators, and distribution board accessories with full specifications and ordering information for global projects.
Download Line CardCompany Profile
Learn more about ElectriHub — your global partner for genuine Schneider Electric circuit protection and switchgear products delivered with technical excellence and after-sales support worldwide.
Download ProfileWhat is a Schneider MCB 16 Amp?
A Schneider MCB 16 Amp (Miniature Circuit Breaker) is a compact, automatically resettable protective device that safeguards electrical circuits rated up to 16A from overload currents and short-circuit faults. The Schneider 16A MCB is one of the most commonly specified current ratings in the entire MCB range — used in virtually every residential consumer unit, commercial distribution board, and light industrial panel for lighting circuits, general purpose socket outlet circuits, dedicated small appliance circuits, and low-current motor feeders. Built to IEC 60898-1 (residential/commercial grade) and IEC 60947-2 (industrial grade) standards across the Acti9 and Easy9 series, the Schneider Electric MCB 16A offers breaking capacities from 6kA through 25kA to suit every installation category. When you buy Schneider MCB 16 Amp from ElectriHub, you receive 100% genuine Schneider Electric products with manufacturer warranty and full technical support.
Schneider 16A MCB — Key Applications in Residential Wiring
The Schneider MCB 16 Amp is the workhorse of residential electrical distribution — the single most common MCB rating found in Indian and Middle Eastern home consumer units. Key residential circuit applications for the 16A MCB include:
- Lighting Circuits: A 16A MCB provides generous headroom for residential lighting circuits — typical LED lighting loads are 1A–4A per circuit, well within the 16A rating. A C curve 16A MCB is standard for all lighting circuits in India. In European installations, B curve is used to maximise cable protection sensitivity on low-current lighting circuits
- General Purpose Socket Outlet Circuits: For residential ring main or radial socket circuits, the 16A MCB protects against overloading from multiple plug-in appliances such as televisions, phone chargers, laptops, desk fans, and small kitchen appliances. In Indian residential wiring, 16A socket circuits are the standard for bedroom and living area socket outlets, typically wired in 2.5mm² cable
- Dedicated Appliance Circuits: Individual circuits for refrigerators, washing machines, dishwashers, and microwave ovens in Indian kitchens are commonly protected by a dedicated Schneider 16A MCB — providing circuit segregation that prevents a fault on one appliance from affecting the entire kitchen or living area distribution
- Air Conditioner Circuits (0.75 Ton – 1 Ton): Small split air conditioners up to approximately 1 ton (3.5kW) with a running current of 5A–8A are protected by a 16A MCB C curve. A C curve is essential — B curve would nuisance-trip on compressor start-up inrush for small AC units
- Water Heater (Geyser) Circuits: Instant water heaters rated up to 3kW (approximately 13A at 230V) are protected by a dedicated 16A MCB — providing individual circuit isolation for the bathroom water heater without affecting other bathroom circuits
Schneider 16A MCB — Key Applications in Commercial and Industrial Wiring
In commercial and industrial distribution boards, the Schneider 16A MCB is equally ubiquitous — serving as the outgoing circuit protection device for a wide range of load types:
- Office Lighting Circuits: Commercial open-plan office lighting circuits — typically fluorescent or LED luminaires totalling 2kW–3kW per circuit — are protected by 16A C curve outgoing MCBs in commercial distribution boards. For offices close to the HV/LV substation where PSCC exceeds 6kA, the Acti9 iC60H 16A 10kA is the mandatory specification
- Power Socket Circuits in Commercial Fit-Outs: Radial socket outlet circuits in commercial offices, retail spaces, and hospitality venues are commonly rated at 16A — protecting computer workstation circuits, point-of-sale equipment circuits, and general power socket rows in conference rooms and open office areas
- HVAC Fan Coil Unit (FCU) Circuits: Individual fan coil unit supply circuits in commercial HVAC systems are typically protected by a dedicated 16A MCB in the floor distribution board — providing isolation and overcurrent protection for each FCU without affecting adjacent circuits. D curve may be specified for FCU circuits with PSC (Permanent Split Capacitor) motors that exhibit moderate inrush
- Server Room and Data Centre PDU Circuits: Outgoing circuit protection at 16A in data centre power distribution units (PDUs) for individual server rack power supply circuits. At this application, the Acti9 iC60H or iC60L 16A is specified to match the high fault current environment of the data centre main distribution infrastructure
- Instrumentation and Control Panel Supply Circuits: 16A MCBs protect 24V DC SMPS, 110V AC UPS outputs, and general control panel auxiliary supply circuits in industrial automation panels. B curve 16A MCBs are often specified here for maximum sensitivity against high-impedance faults on instrumentation wiring
Schneider 16A MCB Part Number Guide
The Schneider 16A MCB part number follows the standard Acti9 format: A9F[curve][poles]16. The curve digit: 7 = C curve, 4 = B curve, 5 = D curve for iC60N; 8 = C curve, 6 = B curve, 9 = D curve for iC60H. The poles digit: 1 = 1-pole, 2 = 2-pole, 3 = 3-pole, 4 = 4-pole. So the most commonly ordered Schneider 16A MCB in India is A9F74116 — Acti9 iC60N, C curve, 1-pole, 16A — used for single-phase outgoing lighting and socket circuits in residential and commercial distribution boards. A9F74216 = iC60N, C curve, 2-pole, 16A — for double-pole isolation on single-phase circuits. A9F74316 = iC60N, C curve, 3-pole, 16A — for three-phase motor or balanced load circuits. For Easy9: EZ9F34116 = Easy9, C curve, 1-pole, 16A — the highest-volume residential MCB in India. Always verify the complete part number with ElectriHub's technical team before ordering for project quantities.
Schneider 16A MCB — Choosing the Right Curve: B, C, or D
The trip curve of the Schneider 16A MCB is critical to both protection performance and avoiding nuisance tripping. At 16A, the three curve options cover very different application profiles:
- B Curve (3–5× In = 48A–80A instantaneous trip): The most sensitive standard curve. Trips instantaneously the moment the fault current reaches 48A–80A. Ideal for LED lighting circuits, electric heating elements, and resistive load circuits where all cable protection is the priority and loads have no inrush current. B curve is the European residential standard and is also used in TT earthing systems where sensitive earth fault protection is required. In India, B curve is less common for domestic wiring but is specified for instrumentation circuits and sub-metered residential panels in premium developments
- C Curve (5–10× In = 80A–160A instantaneous trip): The universal standard curve for general wiring in India and the Middle East. The Schneider 16A MCB C Curve is the correct choice for residential lighting circuits, socket outlet circuits, kitchen appliance circuits, and small air conditioner circuits where moderate inrush on start-up must be tolerated without nuisance tripping. The C curve is the default specification for the vast majority of outgoing MCBs in Indian distribution boards. If in doubt, specify C curve
- D Curve (10–20× In = 160A–320A instantaneous trip): For high-inrush loads only. The Schneider 16A MCB D Curve is specified for small motor circuits (up to approximately 2.2kW at 230V single-phase or 1.5kW at 400V three-phase), transformer primaries, solenoid valve banks, and magnetic ballast lighting circuits where start-up inrush would nuisance-trip a C curve MCB. At 16A, D curve is commonly used for small HVAC FCU motor circuits, pump control circuits, and small three-phase motor feeders in light industrial and commercial HVAC panels. Do not specify D curve for standard lighting or socket circuits — the reduced sensitivity provides insufficient cable protection against high-impedance faults
Schneider 16A MCB vs Schneider 16A RCBO — Understanding the Difference
A common question when designing residential and commercial consumer units is whether to specify a Schneider 16A MCB with a separate RCCB upstream, or replace the MCB with a Schneider 16A RCBO (Residual Current Circuit Breaker with Overcurrent protection — Acti9 iC60 RCBO series). The key differences are:
- MCB alone: Provides overload and short-circuit protection only — no earth fault or residual current protection. Requires a separate RCCB upstream on the incomer to provide earth leakage protection for the group of circuits. More economical for large panels with many outgoing circuits sharing a common RCCB. The limitation is that an earth fault on any one circuit trips the entire RCCB and all circuits on that incomer
- RCBO (MCB + RCD in one device): The Schneider Acti9 iC60 RCBO 16A (e.g., A9D11616 — 1P+N, 30mA, C16A) combines overload, short-circuit, and residual current protection in a single DIN rail module. An earth fault on one circuit trips only that circuit's RCBO — all other circuits remain live. This is the preferred specification for residential consumer units where circuit selectivity and continuity of supply for unaffected circuits is required. Higher individual device cost but eliminates the nuisance tripping issue of shared RCCBs
For modern residential consumer units in India and export markets, ElectriHub recommends the Schneider Acti9 RCBO 16A 30mA for all socket outlet and bathroom circuits, with a standard Schneider 16A MCB C curve for lighting circuits protected by a common 30mA RCCB. Contact our technical team for a complete consumer unit BOM with MCB and RCBO coordination matched to your load schedule.
Schneider Easy9 vs Acti9 iC60N — Which 16A MCB for Residential Use?
The two most common Schneider 16A MCB options for residential consumer units are the Easy9 and the Acti9 iC60N. Both are rated 6kA at 230/400V AC and occupy 18mm per pole on the DIN rail — but there are important practical differences that determine which is the right specification:
- Choose Easy9 when: The consumer unit is a straightforward residential panel with no BMS, no remote trip requirement, and no need for auxiliary contact monitoring. The Easy9 is available in 1P, 2P, and 3P only — no 4-pole option. It has no snap-on accessory system. It is the most economical genuine Schneider MCB available and is the highest-volume residential MCB in India. Ideal for housing developers, residential electricians, and large-scale apartment projects where cost efficiency drives specification
- Choose Acti9 iC60N when: The consumer unit requires BMS integration (iOF auxiliary contact), remote trip capability from a fire alarm or building management system (iSD shunt release), automatic tripping on supply loss (iMN undervoltage release), a 4-pole configuration for TN-S systems, or future-proofing for smart home integration. The iC60N is also dual-rated under IEC 60947-2 — the correct specification for any panel classified as an industrial switchgear assembly. The additional cost over Easy9 is modest and justified in any panel with a BMS or fire safety requirement
Schneider 16A MCB for Three-Phase Motor Feeder Circuits
A Schneider 16A MCB 3-pole specified as a motor feeder circuit breaker protects small three-phase induction motors at 400V AC. At 16A AC-3 rating, a 3-pole MCB can protect motors up to approximately 5.5kW at 400V in a direct-on-line (DOL) start configuration — however, the correct specification depends on the motor's full load current (FLC) and starting method. For DOL starting of small motors, the Schneider Acti9 iC60N or iC60H 16A 3-pole D curve (A9F54316 or A9F94316) is the standard specification — the D curve prevents nuisance tripping on DOL inrush (typically 6–8× FLC) while providing short-circuit protection. For star-delta starting, a C curve may be acceptable as the DOL inrush is reduced. For motors above 5.5kW, a dedicated motor protection circuit breaker (Schneider GV2 or GV3) with matching contactor and overload relay is the preferred and more technically correct solution. Contact ElectriHub's technical team for motor feeder MCB selection matched to your motor kW and starting method.
Buy Schneider MCB 16 Amp Online from ElectriHub
ElectriHub is your trusted one-stop platform to buy Schneider 16A MCB online — from the value-range Easy9 for high-volume residential projects to the Acti9 iC60L 25kA for critical industrial panels, across all curve types (B, C, D), pole configurations (1P, 2P, 3P, 4P), and breaking capacities (6kA, 10kA, 15kA, 25kA), along with the full Acti9 accessory range including iOF auxiliary contacts, iSD shunt releases, iMN undervoltage releases, rotary handles, and comb busbars. We supply 100% genuine Schneider Electric products with manufacturer warranty, competitive pricing for single units and bulk project orders, fast worldwide shipping with export documentation, and free pre-sales technical support from qualified electrical engineers. Whether you are a residential electrician ordering Easy9 MCBs for a flat consumer unit, a panel builder specifying Acti9 iC60N MCBs for a commercial distribution board, or an industrial engineer sourcing high breaking capacity iC60L units for a critical facility — ElectriHub is your preferred source for Schneider MCB 16 Amp online.
Why Buy Schneider 16A MCB from ElectriHub?
- ✓ Complete Schneider 16A MCB range — Acti9 iC60N, iC60H, iC60L, Easy9, and Domae in 1P, 2P, 3P, and 4P
- ✓ All curve types available — B, C, and D curve in 6kA, 10kA, 15kA, and 25kA breaking capacities
- ✓ Matching Acti9 RCBO 16A available — 30mA and 300mA in 1P+N for individual circuit earth leakage protection
- ✓ Full Acti9 accessory range — iOF auxiliary contacts, iSD shunt releases, iMN undervoltage releases, and comb busbars
- ✓ 100% genuine Schneider Electric products with IEC 60898-1 / IEC 60947-2 certification and manufacturer warranty
- ✓ BIS-certified products available for Indian market compliance
- ✓ Competitive pricing with volume discounts for panel builders, EPC contractors, and residential developers
- ✓ Complete consumer unit MCB sets — matched by circuit schedule on request for residential and commercial projects
- ✓ Worldwide shipping with full tracking and export documentation
- ✓ Technical pre-sales support — curve selection, breaking capacity verification, MCB vs RCBO decisions, and panel design guidance
- ✓ Fast dispatch from our global warehouse — urgent orders dispatched same or next business day
- ✓ Dedicated account managers for EPC firms, panel builders, residential developers, and project orders
Frequently Asked Questions
Q: What is the most commonly ordered Schneider 16A MCB in India?
The highest-volume Schneider 16A MCB sold in India is the Schneider Easy9 16A MCB 1-pole C curve (EZ9F34116) — used in virtually every residential flat consumer unit for outgoing lighting and socket circuits. For residential panels where BMS compatibility or IEC 60947-2 industrial rating is required, the Acti9 iC60N 16A 1-pole C curve (A9F74116) is the standard specification. Both are stocked by ElectriHub with same or next-day dispatch for urgent project requirements.
Q: Can I use a Schneider 16A MCB for a 1.5-ton air conditioner circuit?
A 1.5-ton split air conditioner in India typically has a running current of approximately 8A–10A at 230V single-phase. A Schneider 16A MCB C curve provides adequate rated current headroom (16A rated, tripping at 1.45× = 23.2A thermally) and the C curve instantaneous trip (80A–160A) tolerates the compressor start-up inrush without nuisance tripping. However, for larger 1.5-ton models with a full load current above 12A, or for inverter-type ACs with high start-up inrush, a 20A MCB may be the more appropriate specification — always check the AC nameplate data for the rated current and recommend using a cable and MCB rated at least 125% of the nameplate FLC. Contact ElectriHub's technical team for MCB size confirmation against your specific AC unit model.
Q: What is the difference between Schneider Easy9 16A MCB and Acti9 iC60N 16A MCB?
The Easy9 16A MCB is rated under IEC 60898-1 only — suitable for residential and commercial consumer units. It is available in 1P, 2P, and 3P without snap-on accessory support (no iOF, iSD, or iMN compatibility). The Acti9 iC60N 16A MCB is dual-rated under IEC 60898-1 and IEC 60947-2 — available in 1P to 4P with the full Acti9 modular accessory system. For panels requiring BMS monitoring, remote trip, fire alarm integration, or 4-pole switching, the iC60N is the mandatory choice. For straightforward residential final circuits with no accessory requirements, the Easy9 offers the best value.
Q: Should I use a 16A MCB or 16A RCBO for socket outlet circuits?
For residential socket outlet circuits, modern best practice — and the requirement under IS 732 (Indian Standard for electrical wiring) for circuits in bathrooms, kitchens, and outdoor areas — is to use a Schneider 16A RCBO (30mA) for individual circuit earth leakage protection rather than a plain 16A MCB with a shared upstream RCCB. The RCBO ensures that an earth fault on any single socket circuit trips only that circuit — not the entire group protected by the shared RCCB. The Schneider Acti9 iC60 RCBO 16A 30mA 1P+N (A9D11616) is the recommended specification for all socket outlet and bathroom circuits in residential consumer units. For lighting circuits in areas away from water, a standard Schneider 16A MCB C curve protected by a 30mA RCCB upstream is acceptable. Contact ElectriHub for a complete consumer unit MCB and RCBO specification matched to your floor plan.
Q: Is Schneider Easy9 16A MCB BIS certified for use in India?
Yes. The Schneider Easy9 MCB range, including the 16A variant, is BIS (Bureau of Indian Standards) certified under IS/IEC 60898-1 — the mandatory certification for MCBs sold in India for residential and commercial applications. Genuine Schneider Electric Easy9 and Acti9 MCBs purchased from authorised distributors like ElectriHub carry BIS certification markings and Schneider Electric's product authenticity features. Counterfeit Schneider MCBs are prevalent in the Indian online market — always purchase from an authorised distributor to ensure genuine BIS-certified products that meet the declared breaking capacity and trip accuracy specifications.
Q: Do you ship Schneider MCB 16 Amp internationally?
Yes. ElectriHub ships Schneider MCB 16 Amp products — all series, curve types, pole configurations, and breaking capacities — to customers worldwide. We provide complete export documentation including commercial invoices, packing lists, certificates of origin, and MSDS where required. Contact our team with your Schneider 16A MCB part number (e.g., A9F74116 or EZ9F34116), quantity, and delivery destination for a fast shipping quotation and lead time confirmation.
Order Your Schneider MCB 16 Amp Today
Ready to buy Schneider 16A MCB online? Browse our complete range above — Acti9 iC60N, iC60H, iC60L, Easy9, and Domae in all curve types, pole configurations, and breaking capacities — along with matching Acti9 RCBOs, iOF auxiliary contacts, iSD shunt releases, comb busbars, and DIN rail enclosures, or contact our technical team for MCB selection support, RCBO vs MCB guidance, breaking capacity verification, and complete consumer unit or distribution board BOM specification. ElectriHub ships genuine Schneider MCB 16 Amp worldwide and supports projects of all sizes — from a single replacement MCB to complete housing development consumer unit builds. Get 100% authentic Schneider 16A MCBs with fast dispatch, competitive pricing, and full technical support — only at ElectriHub.
Connectors
Electrical Conduits and Fittings
EV Chargers
Home Automation
Mixed Products
Power Supplies and Tools
Rack Power Distribution
Low Voltage Breakers
Contactors and Contactor Relays
Home Distribution Products
Power Monitoring & PF Correction
Changeover Switches & Isolators
Industrial Automation Products
Signalling and Controlling
Medium Voltage Products
Wires & Cables
Industrial Motors
Pumps