Buy Schneider Auxiliary Contactor Online – 2NO+2NC, 1NO+1NC, 3NO+1NC, 4NO & More | ElectriHub

Buy Schneider Auxiliary Contactor Online – TeSys D & TeSys K, 1NO+1NC, 2NO+2NC, 3NO+1NC, 3NO+2NC & 4NO Configurations

ElectriHub is your authorised global source to buy Schneider auxiliary contactor online — the complete Schneider Electric TeSys auxiliary contactor range covering every standard contact configuration, including Schneider auxiliary contactor 1NO+1NC, Schneider auxiliary contactor 2NO+2NC, Schneider auxiliary contactor 3NO+1NC, Schneider auxiliary contactor 3NO+2NC, and Schneider 4NO auxiliary contactor — alongside mixed and special-configuration variants for standalone DIN-rail auxiliary contactor and add-on block applications. Schneider Electric's TeSys auxiliary contactors are built around two primary platform families: the TeSys D series — the global standard Schneider auxiliary contactor range for standalone control circuit switching, built around the LADN and CAD series — and the TeSys K series for compact, cost-optimised auxiliary contactor applications. Available in AC and DC coil voltages from 24V to 415V, with standard 4-pole and multi-pole contact configurations across normally open (NO) and normally closed (NC) contact arrangements, Schneider TeSys auxiliary contactors are IEC 60947-5-1 compliant, CE marked, and engineered for seamless integration alongside the full TeSys D main contactor and protection relay ecosystem. Every Schneider auxiliary contactor supplied by ElectriHub is 100% genuine, fully warranted, and available with worldwide shipping and expert technical support. Buy Schneider auxiliary contactor online — any contact configuration, any coil voltage — only at ElectriHub.

✓ All Contact Configurations In Stock

1NO+1NC, 2NO+2NC, 3NO+1NC, 3NO+2NC, 4NO, 4NC, and mixed-pole special variants — the complete Schneider TeSys auxiliary contactor contact configuration range stocked globally at ElectriHub for same or next business day dispatch.

✓ TeSys D (LADN / CAD) – Global Standard Platform

The LADN-series Schneider auxiliary contactor is the worldwide benchmark for control circuit switching in motor control, automation, and building services panels — available in every NO/NC contact combination, AC and DC coil voltages from 24V to 415V, and full accessory compatibility with the TeSys D main contactor range.

✓ TeSys K – Compact Auxiliary Contactor

The TeSys K auxiliary contactor series delivers a compact DIN-rail footprint for cost-sensitive and space-constrained OEM panel and machine building applications — available in the most common contact configurations and coil voltages for small motor control and control circuit switching duties.

✓ 100% Genuine Schneider Electric Products

Every Schneider auxiliary contactor supplied by ElectriHub is 100% authentic Schneider Electric product — IEC 60947-5-1 compliant, CE marked — with full manufacturer warranty. No grey-market or counterfeit products across any contact configuration or coil voltage variant.

✓ AC & DC Coil Voltages Available

Schneider TeSys auxiliary contactors are stocked at ElectriHub across the full AC coil voltage range (24V, 48V, 110V, 220V/230V, 240V, 380V/400V, 415V) and DC coil voltages (24VDC, 48VDC, 110VDC) — covering control circuit voltage requirements for global panel builds across all markets.

✓ Worldwide Shipping & Technical Support

Fast international dispatch for the full Schneider auxiliary contactor range — with complete export documentation, full shipment tracking, and expert pre-sales support for contact configuration selection, coil voltage confirmation, and TeSys D main contactor compatibility guidance for your panel build.

4-Pole Standard Contact Configuration
1NO+1NC to 4NO / 4NC Contact Arrangements Available
24V – 415V AC / DC Coil Voltage Range
10A @ AC-15 Rated Operational Current
TeSys D / TeSys K Product Platform
IEC 60947-5-1 Compliance Standard

Buy Schneider Auxiliary Contactor by Contact Configuration

1NO + 1NC

Schneider Auxiliary Contactor 1NO+1NC

1 Normally Open + 1 Normally Closed contact. LADN11 (TeSys D) — the most compact and cost-efficient standard configuration. Used for single interlock and status signalling duties.

2NO + 2NC

Schneider Auxiliary Contactor 2NO+2NC

2 Normally Open + 2 Normally Closed contacts. LADN22 (TeSys D) — the most widely specified balanced configuration for motor starter interlock, auxiliary signalling, and PLC feedback circuits.

3NO + 1NC

Schneider Auxiliary Contactor 3NO+1NC

3 Normally Open + 1 Normally Closed contact. LADN31 (TeSys D) — widely used where multiple parallel signal paths and one interlock or safety NC contact are required in one device.

3NO + 2NC

Schneider Auxiliary Contactor 3NO+2NC

3 Normally Open + 2 Normally Closed contacts. 5-pole TeSys D variant — for applications requiring multiple NO signal paths alongside two independent NC interlocks or safety contacts.

4NO

Schneider 4NO Auxiliary Contactor

4 Normally Open contacts. LADN40 (TeSys D) — the all-NO configuration for applications requiring maximum parallel make contacts for multi-circuit simultaneous energisation or signalling.

4NC

Schneider 4NC Auxiliary Contactor

4 Normally Closed contacts. LADN04 (TeSys D) — all-NC configuration for safety interlock, de-energisation signalling, and fail-safe control applications requiring maximum break contacts.

1NO + 3NC

Schneider Auxiliary Contactor 1NO+3NC

1 Normally Open + 3 Normally Closed contacts. LADN13 (TeSys D) — for applications with dominant NC interlock requirements alongside a single make contact for local indication or auxiliary signalling.

2NO + 1NC

Schneider Auxiliary Contactor 2NO+1NC

2 Normally Open + 1 Normally Closed contact. LADN21 (TeSys D) — compact 3-pole configuration used where two NO signal paths and one NC interlock are required in a compact form factor.

Buy Schneider Auxiliary Contactor Online by Series

Schneider LADN22 TeSys D Auxiliary Contactor 2NO+2NC 24V 110V 220V 415V AC Coil
LADN22 – 2NO+2NC | TeSys D

Schneider LADN22 – Auxiliary Contactor 2NO+2NC (TeSys D)

View Products
Schneider LADN11 TeSys D Auxiliary Contactor 1NO+1NC AC Coil
LADN11 – 1NO+1NC | TeSys D

Schneider LADN11 – Auxiliary Contactor 1NO+1NC (TeSys D)

View Products
Schneider LADN31 TeSys D Auxiliary Contactor 3NO+1NC AC Coil
LADN31 – 3NO+1NC | TeSys D

Schneider LADN31 – Auxiliary Contactor 3NO+1NC (TeSys D)

View Products
Schneider TeSys D Auxiliary Contactor 3NO+2NC 5-Pole AC DC Coil
3NO+2NC – 5-Pole | TeSys D

Schneider TeSys D – Auxiliary Contactor 3NO+2NC (5-Pole)

View Products
Schneider TeSys K Auxiliary Contactor Compact 2NO+2NC CAD32 CAD22 AC DC Coil
TeSys K – Compact Auxiliary Contactor

Schneider TeSys K – Compact Auxiliary Contactor (CAD Series, 2NO+2NC & More)

View Products

Schneider Auxiliary Contactor – Contact Configuration & Catalogue Number Guide

Contact Configuration TeSys D Catalogue Ref. NO Contacts NC Contacts Total Poles Typical Application
1NO + 1NC LADN11 1 1 2 Single interlock and auxiliary signalling — the most compact and economical TeSys D auxiliary contactor; used for single-pole make and break control circuit duties in simple motor starters and signalling circuits
2NO + 1NC LADN21 2 1 3 Two parallel make contacts for auxiliary signalling or circuit energisation alongside one normally closed interlock contact; compact 3-pole configuration for intermediate-complexity motor starter auxiliary circuits
2NO + 2NC LADN22 2 2 4 The most widely specified Schneider auxiliary contactor configuration — balanced 4-pole 2NO+2NC for motor starter interlocking, PLC feedback, auxiliary signalling, reversing starter interlock, and general control circuit switching duties across the full TeSys D motor control ecosystem
3NO + 1NC LADN31 3 1 4 Three normally open contacts for multiple simultaneous circuit energisation or signalling paths, plus one normally closed contact for interlock or safety signalling; widely used in star-delta starter auxiliary circuits, multi-output PLC interface circuits, and automation panels requiring multiple simultaneous make paths
1NO + 3NC LADN13 1 3 4 Three normally closed contacts for dominant NC interlock, safety, or de-energisation signalling applications with a single make contact for auxiliary indication; used in safety relay interface panels, process interlocking, and emergency shutdown signal routing
4NO LADN40 4 0 4 All normally open — four simultaneous make contacts for maximum parallel circuit energisation; used in multi-circuit lighting control, parallel output PLC interface, multiple pilot lamp energisation, and any application requiring maximum NO contacts in one auxiliary contactor device
4NC LADN04 0 4 4 All normally closed — four simultaneous break contacts for safety interlock, fail-safe de-energisation, and emergency stop signal routing; used in safety relay cascading, process safety shutdown panels, and applications requiring the maximum number of NC contacts in a single auxiliary contactor
3NO + 2NC CAD50 / Special TeSys D variant 3 2 5 5-pole configuration — three make contacts for multiple simultaneous signal outputs alongside two independent NC interlocks; used in complex motor starter panels, automation interface circuits, and star-delta or reversing starters requiring extended auxiliary contact capability beyond the standard 4-pole auxiliary contactor range
TeSys K – 2NO+2NC CAD32BD / CAD22BD (DC) / CAD22 (AC) 2 2 4 Compact auxiliary contactor for cost-sensitive OEM panel, machine building, and small motor control applications where the standard TeSys D footprint is not required; available in AC and DC coil voltages including 24VDC for PLC-driven control circuits

Catalogue references shown are indicative TeSys D (LADN series) and TeSys K (CAD series) base type numbers. Full catalogue numbers include a coil voltage suffix — for example, LADN22 with 220V AC coil = LADN22M7 or LADN22 with 24V DC coil = LADN22BD. Contact ElectriHub's technical team to confirm the exact catalogue number for your required contact configuration and coil voltage.

Schneider Auxiliary Contactor – Coil Voltage Reference Guide

Coil Voltage Coil Type Catalogue Suffix (LADN Series) Typical Market / Application Notes
24V AC AC B7 (e.g. LADN22B7) Machine control panels, OEM equipment with 24V AC control circuits Suitable for 24V AC single-phase control transformers; confirm 50Hz or 60Hz coil frequency requirement
24V DC DC BD (e.g. LADN22BD) PLC-driven control circuits; the most widely used DC coil voltage for modern automation panels globally; no AC inrush current surge DC coil — no residual magnetism issues; suitable for PLC transistor output (source/sink) direct switching; fastest operate/release times
48V AC AC E7 (e.g. LADN22E7) Legacy European machine control panels; 48V AC control transformer installations Less common than 24V or 110V AC; confirm availability with ElectriHub for specific configuration and coil voltage combination
48V DC DC EL (e.g. LADN22EL) Process industry 48VDC auxiliary power rail panels; some railway and transit signalling applications DC coil; confirm availability with ElectriHub for your specific contact configuration
110V AC AC F7 (e.g. LADN22F7) Middle East, North America (60Hz), and industrial panels using 110V AC control circuits; widely used in Indian industrial switchgear with 110V AC control transformers Confirm 50Hz or 60Hz coil — separate suffix variants exist; 110V AC is the standard control voltage for many Indian MCC panels
110V DC DC FL (e.g. LADN22FL) Substation and power industry DC control panels; legacy 110VDC station battery-fed auxiliary control circuits DC coil; used in power utility and substation switchgear panels where 110VDC station battery supplies the control circuit
220V / 230V AC AC M5 or M7 (e.g. LADN22M7) Single-phase 230V AC control circuits in European and Asian industrial panels; widely stocked at ElectriHub for global supply 220V AC and 230V AC coils may share the same catalogue suffix depending on variant — confirm with ElectriHub for your installation
240V AC AC U7 (e.g. LADN22U7) UK, Australian, and South Asian markets with 240V single-phase control circuits; common in Indian industrial panels with 240V control voltage 240V AC coil — widely stocked for Indian and export markets; confirm frequency (50Hz/60Hz) for your installation
380V / 400V AC AC Q5 or Q7 (e.g. LADN22Q7) Panels using line-to-line 3-phase voltage for the control circuit without a separate control transformer; European 400V AC three-phase panels Less common for auxiliary contactor coils — used where no control transformer is fitted and the coil is energised directly from the 3-phase supply line voltage
415V AC AC N5 (e.g. LADN22N5) Indian and South Asian panels using 415V line-to-line for coil energisation; MCC assemblies without a step-down control transformer where the auxiliary contactor coil is connected directly to the 415V supply 415V AC coil — frequently specified in Indian industrial panels; widely stocked at ElectriHub for India and export markets

Coil voltage suffix codes shown are representative TeSys D LADN-series references. Full catalogue number confirmation — including coil voltage suffix, contact configuration, and any special variants (AC/DC, sealed coil, low consumption) — should be verified with ElectriHub's technical team before ordering.

TeSys D vs TeSys K – Choosing the Right Schneider Auxiliary Contactor Platform

Feature TeSys D Auxiliary Contactor (LADN / CAD Series) TeSys K Auxiliary Contactor (CAD Series)
Platform Generation Schneider's globally proven, highest-volume auxiliary contactor platform — the TeSys D (LADN/CAD series) is the worldwide standard Schneider auxiliary contactor, installed across decades of industrial, infrastructure, and building services panels globally Schneider's compact, cost-engineered auxiliary contactor platform — the TeSys K CAD series offers a smaller DIN rail footprint and lower unit cost for OEM machine panel and small motor control applications where the full TeSys D feature set is not required
Contact Configurations Available Full range: 1NO+1NC (LADN11), 2NO+1NC (LADN21), 2NO+2NC (LADN22), 3NO+1NC (LADN31), 1NO+3NC (LADN13), 4NO (LADN40), 4NC (LADN04), and 5-pole 3NO+2NC variants — the widest Schneider auxiliary contactor configuration range available Most common configurations: 2NO+2NC (CAD22), 3NO+1NC (CAD32), and selected others — a narrower range than TeSys D; for less-common configurations, TeSys D (LADN series) is recommended
Rated Current (AC-15) 10A at AC-15 (230V) — suitable for the vast majority of control circuit switching duties in industrial motor control, MCC, and building services panels 6A at AC-15 — adequate for OEM machine panel and small motor control circuit switching duties; lower than TeSys D for high-load control circuit applications
Coil Voltage Range Full coil voltage range: 24V to 415V AC and 24V to 110V DC — covering every global control circuit voltage requirement; all coil voltages stocked at ElectriHub Limited coil voltage range — most common variants available in 24VDC, 24V AC, 110V AC, 220–240V AC; less comprehensive than TeSys D for non-standard coil voltages
DIN Rail Footprint Standard 45mm width DIN rail auxiliary contactor footprint — the reference footprint for TeSys D ecosystem panel designs Compact footprint — narrower DIN rail width than TeSys D; well-suited to space-constrained OEM machine and small panel applications
TeSys Main Contactor Compatibility Fully compatible alongside TeSys D LC1-D / LC1-E main contactors as a standalone auxiliary contactor or in combination with LA1-DN add-on auxiliary contact blocks for expanded contact count Standalone DIN-rail auxiliary contactor — typically not used as a direct add-on to TeSys D main contactors; used separately on the DIN rail rather than block-mounted
Typical Use Case The default choice for the vast majority of industrial auxiliary contactor applications — motor starter panels, MCC auxiliary circuits, reversing starter interlocking, PLC interface, building services motor control, and infrastructure electrical rooms High-volume, cost-sensitive OEM machine panel builds and small motor control applications where a compact DIN-rail auxiliary contactor with a limited contact configuration range is sufficient and unit cost is the primary driver
Cost Standard pricing for a full-specification industrial auxiliary contactor — reflects the wider contact configuration range, higher rated current, and full coil voltage coverage of the TeSys D platform Generally more economical per unit than TeSys D — a lower-cost alternative when the compact form factor and reduced contact current rating are acceptable

Schneider Auxiliary Contactor Applications

Motor Starter Interlocking (Reversing Starters)

The Schneider 2NO+2NC auxiliary contactor (LADN22) is the standard device for electrical interlocking in reversing motor starters — with one 2NO+2NC auxiliary contactor in the forward contactor circuit and one in the reverse contactor circuit, the NC contacts prevent simultaneous energisation of both contactors, eliminating phase-to-phase short circuits across the reversing pair.

PLC Digital Output Interface

Schneider TeSys D auxiliary contactors with 24VDC coil (LADN series BD suffix) are the standard interface device between PLC transistor digital outputs and higher-voltage/higher-current control circuits — the 24VDC coil is directly switchable by PLC transistor output cards (NPN/PNP), protecting the PLC output from inductive loads and isolating the control voltage level from the field circuit.

Star-Delta Starter Auxiliary Circuits

The Schneider 3NO+1NC auxiliary contactor (LADN31) is frequently used in star-delta starter auxiliary control circuits — where multiple simultaneous make contacts are required to energise the timer relay, pilot lamps, and remote status outputs simultaneously with a single NC interlock contact for safety or feedback signalling.

MCC Auxiliary Control & Status Signalling

Schneider LADN22 (2NO+2NC) auxiliary contactors are the standard signalling device in MCC (Motor Control Centre) outgoing feeder auxiliary circuits — providing local/remote status indication, run/fault feedback to SCADA, and interlock between manual local and remote automatic control modes in industrial process plant MCCs.

Safety Interlock Circuits

The Schneider 4NC auxiliary contactor (LADN04) and 1NO+3NC (LADN13) are specified in machine safety interlock circuits, emergency stop relay cascading, and process safety shutdown panels where the maximum number of normally closed break contacts in a single device is required for fail-safe de-energisation signal routing.

Multi-Circuit Lighting & Heating Control

The Schneider 4NO auxiliary contactor (LADN40) provides four simultaneous make contacts for multi-circuit lighting, heating, or auxiliary load switching applications — where a single coil energisation must simultaneously energise up to four independent load circuits, pilot lamps, or downstream relay coils.

Building Management System (BMS) Interface

Schneider TeSys D auxiliary contactors — typically LADN22 (2NO+2NC) with 24VDC or 230V AC coils — are the standard BMS-to-field interface device for building services motor control: fan coil units, AHU starters, chiller auxiliaries, and HVAC motor run/status signalling in commercial building electrical rooms and BMS control panels.

Remote Run/Stop Control of Motor Starters

A Schneider auxiliary contactor wired as a latching (self-holding) relay circuit — using a NO contact in series with the start pushbutton to maintain the coil circuit after the start button is released — is the classic motor starter remote run/stop control circuit used across decades of Indian and global industrial motor starter panel designs.

Alarm & Fault Annunciation Panels

Schneider LADN22 and LADN31 auxiliary contactors relay fault, trip, and alarm signals from motor protection relays, MPCB trip contacts, and overload relay auxiliary contacts to annunciator panels, SCADA digital inputs, and remote alarm systems — providing the voltage isolation and contact multiplication required between the protection device output and the monitoring system input.

Automation & Machine Tool Control

Schneider TeSys K auxiliary contactors (CAD series, 24VDC coil) are widely used in OEM machine tool, CNC, packaging, and textile machine control panels — providing compact DIN-rail auxiliary contact switching for axis interlock, safety gate monitoring relay circuits, and machine state output signalling to operator HMI interfaces.

Contactor Replacement & Panel Retrofit

Schneider LADN-series auxiliary contactors are the standard replacement auxiliary contactor for retrofit and panel upgrade projects across TeSys D and legacy Telemecanique motor starter panels — with direct physical and electrical compatibility across decades of TeSys D ecosystem installations, eliminating the need for panel rewiring or DIN rail modification.

Timer & Counter Relay Coil Switching

Schneider auxiliary contactors switch timer relay (RE7, RE8 series) and counter relay coil circuits in sequential automation control — where PLC outputs or mechanical pushbuttons at low current capacity are used to drive higher-current coil loads via the Schneider TeSys D auxiliary contactor as the intermediate switching device.

Contact Us

Need help selecting the right Schneider auxiliary contactor — contact configuration (2NO+2NC, 1NO+1NC, 3NO+1NC, 4NO, or others) and coil voltage? Our technical team is ready to assist with TeSys D vs TeSys K platform selection, coil voltage catalogue suffix confirmation, and contact configuration guidance for your panel build.

Contact Now

Download Our Product Line Card

Get a detailed overview of our complete product range with specifications and key features across all brands and product families we supply worldwide, including the full Schneider TeSys auxiliary contactor and motor control range.

Download Line Card

Check Our Company Profile

Learn more about ElectriHub — our company profile, global capabilities, and the full range of Schneider Electric control and protection products we supply worldwide for industrial, OEM, and infrastructure projects.

Download Profile

Buy Schneider Auxiliary Contactor Online – Complete TeSys D & TeSys K Range Overview

When you buy Schneider auxiliary contactor online from ElectriHub, you gain access to the complete Schneider Electric TeSys auxiliary contactor range — every standard contact configuration and coil voltage in one catalogue. The Schneider TeSys D LADN-series auxiliary contactor is the global benchmark for control circuit switching in motor starter panels, MCCs, automation cabinets, and building services electrical rooms worldwide — available in 1NO+1NC (LADN11), 2NO+1NC (LADN21), 2NO+2NC (LADN22), 3NO+1NC (LADN31), 1NO+3NC (LADN13), 4NO (LADN40), 4NC (LADN04), and 3NO+2NC 5-pole variants. Coil voltages span the full global range: 24VDC, 24V AC, 48V AC, 110V AC, 110VDC, 220–230V AC, 240V AC, 380–400V AC, and 415V AC — covering every control circuit voltage requirement for Indian and international panel builds. The compact TeSys K CAD-series auxiliary contactor extends the range to cost-sensitive OEM machine panel applications. Every Schneider auxiliary contactor supplied by ElectriHub is IEC 60947-5-1 compliant, CE marked, and available globally with full technical support and worldwide shipping.

Schneider Auxiliary Contactor 2NO+2NC – LADN22 Deep Dive

The Schneider auxiliary contactor 2NO+2NC — catalogue type LADN22 in the TeSys D range — is the most widely specified Schneider Electric auxiliary contactor configuration globally. With two normally open (NO) contacts for circuit make and two normally closed (NC) contacts for interlock and break duties, the LADN22 provides the balanced 4-pole configuration required for the vast majority of motor starter interlock, PLC feedback, reversing starter electrical interlock, SCADA status signalling, and auxiliary circuit switching applications in industrial and building services panels. The LADN22 is available in every standard coil voltage — from 24VDC (LADN22BD) for PLC-driven control circuits to 415V AC (LADN22N5) for Indian panel applications without a step-down control transformer — with all voltage variants stocked at ElectriHub for same or next business day dispatch.

Schneider Auxiliary Contactor 1NO+1NC – LADN11

The Schneider auxiliary contactor 1NO+1NC (LADN11) is the most compact and economical TeSys D auxiliary contactor — providing a single normally open and a single normally closed contact in the smallest TeSys D form factor. The LADN11 is used where only a single make contact and a single break contact are required — simple motor run/stop signalling, single interlock circuits, and control panels with limited auxiliary contact requirements. Its compact size and lower unit cost make the LADN11 the first choice where contact multiplication beyond a single NO+NC pair is not needed.

Schneider Auxiliary Contactor 3NO+1NC – LADN31

The Schneider auxiliary contactor 3NO+1NC (LADN31) provides three normally open contacts for simultaneous multiple-circuit energisation alongside one normally closed contact for interlock or safety signalling — the standard choice for star-delta starter auxiliary circuits, multi-output PLC interface panels, and automation applications requiring multiple simultaneous NO outputs with a single NC interlock. The LADN31 is available in the same full coil voltage range as the LADN22, and ElectriHub stocks the most common coil voltages for same or next business day dispatch.

Schneider Auxiliary Contactor 3NO+2NC – 5-Pole Configuration

The Schneider auxiliary contactor 3NO+2NC is a 5-pole extended contact configuration within the TeSys D range — providing three normally open contacts for multiple simultaneous output paths alongside two independent normally closed contacts for interlock and safety signalling. This configuration is used in complex motor starter panels, star-delta starters with extended auxiliary circuit requirements, and automation interface panels where the standard 4-pole LADN22 or LADN31 contact count is insufficient. Contact ElectriHub's technical team to confirm the exact TeSys D or CAD-series catalogue number for the 3NO+2NC configuration at your required coil voltage.

Schneider 4NO Auxiliary Contactor – LADN40

The Schneider 4NO auxiliary contactor (LADN40) provides four normally open contacts for maximum simultaneous make capability — the all-NO configuration for multi-circuit lighting control, parallel load energisation, multiple pilot lamp switching, and any application where the maximum number of normally open contacts in a single auxiliary contactor device is required. The LADN40 is available in the same coil voltage range as other TeSys D LADN-series auxiliary contactors — contact ElectriHub for stock confirmation and coil voltage options.

How to Select the Right Schneider Auxiliary Contactor – Step-by-Step

  1. Determine the Required Contact Configuration: Count the number of normally open (NO) and normally closed (NC) contacts required for your circuit — interlock contacts are typically NC, signal and energisation contacts are typically NO. Select the LADN configuration that best matches: LADN11 (1NO+1NC), LADN22 (2NO+2NC), LADN31 (3NO+1NC), LADN40 (4NO), LADN04 (4NC), or the 3NO+2NC 5-pole variant for extended contact requirements.
  2. Select Coil Voltage: Identify the control circuit voltage of your panel — 24VDC (most common for PLC panels), 24V AC, 110V AC, 220–230V AC, 240V AC, or 415V AC for Indian panels. Match to the correct LADN coil suffix (BD for 24VDC, F7 for 110V AC, N5 for 415V AC, etc.).
  3. TeSys D or TeSys K: Select TeSys D (LADN series) for the full configuration range, highest rated current (10A at AC-15), widest coil voltage coverage, and direct compatibility with TeSys D LC1-D main contactors. Select TeSys K (CAD series) only where a compact footprint and lower unit cost are the primary drivers and the reduced current rating is acceptable.
  4. Confirm Contact Current Rating: TeSys D auxiliary contactors are rated 10A at AC-15 (230V) — adequate for the vast majority of control circuit coil, lamp, and PLC input card loads. For higher current switching duties in the control circuit, consult ElectriHub's technical team for the correct device.
  5. Check AC or DC Coil: DC coils (24VDC, 48VDC, 110VDC) are recommended for PLC-driven applications — no inrush current, faster operate/release times, and direct PLC transistor output compatibility. AC coils are used for direct energisation from the AC control circuit bus without a PLC interface.
  6. Specify Quantity and Delivery: Contact ElectriHub with the LADN catalogue type, coil voltage suffix, quantity, and delivery destination for a fast quotation — volume pricing available for panel builders, MCC manufacturers, OEMs, and EPC contractors.

Why Buy Schneider Auxiliary Contactor from ElectriHub?

  • ✓ Complete Schneider TeSys D and TeSys K auxiliary contactor range — all contact configurations (1NO+1NC, 2NO+2NC, 3NO+1NC, 3NO+2NC, 4NO, 4NC, and more) stocked globally at ElectriHub
  • ✓ All coil voltages in stock — 24VDC through 415V AC — covering every global control circuit voltage requirement for Indian, European, Middle Eastern, and international panel builds
  • ✓ 100% genuine Schneider Electric products — IEC 60947-5-1 compliant, CE marked — with full manufacturer warranty on every unit supplied
  • ✓ Technical support for contact configuration selection, coil voltage catalogue suffix confirmation, and TeSys D ecosystem compatibility guidance
  • ✓ Competitive pricing with volume discounts for OEMs, panel builders, MCC manufacturers, EPC contractors, and large project orders across all Schneider auxiliary contactor configurations
  • ✓ Worldwide shipping with full tracking and export documentation — urgent orders dispatched same or next business day for standard stocked Schneider auxiliary contactor variants

Frequently Asked Questions – Buy Schneider Auxiliary Contactor Online

Q: What is the difference between a Schneider auxiliary contactor and a Schneider main contactor?

A Schneider main contactor (TeSys D LC1-D series) is a power switching device for making and breaking the main 3-phase or single-phase power circuit to a motor or load — rated for power circuit currents from 9A to 800A+ at AC-3, with three main power contacts and built-in auxiliary contacts. A Schneider auxiliary contactor (TeSys D LADN series) is a control circuit switching device — it has no main power contacts and is rated only for the lower currents of control circuit duty (10A at AC-15 for TeSys D) — used for interlocking, signalling, PLC interfacing, and auxiliary circuit switching alongside or independently of the main contactor.

Q: What does 2NO+2NC mean in a Schneider auxiliary contactor?

In a Schneider auxiliary contactor 2NO+2NC (LADN22), the contact configuration means the device has 2 Normally Open (NO) contacts and 2 Normally Closed (NC) contacts — 4 poles total. When the auxiliary contactor coil is de-energised (off), the 2 NO contacts are open (circuit broken) and the 2 NC contacts are closed (circuit made). When the coil is energised (on), the 2 NO contacts close (circuit made) and the 2 NC contacts open (circuit broken). This balanced 4-pole configuration is the most versatile standard auxiliary contactor configuration, enabling simultaneous circuit energisation (via NO contacts) and interlock or signalling (via NC contacts) in a single device.

Q: Which Schneider auxiliary contactor coil voltage should I use for a PLC-controlled panel?

For a PLC-driven control panel, the recommended Schneider auxiliary contactor coil voltage is 24VDC — catalogue suffix BD (e.g. LADN22BD for 2NO+2NC, 24VDC coil). The 24VDC coil is directly switchable by PLC transistor digital output cards (NPN or PNP), with no AC inrush current surge, faster operate and release times than AC coils, and simple wiring from the 24VDC auxiliary power supply typically available in any PLC control panel. For panels without a PLC and with an AC control bus, select the coil voltage matching your control transformer secondary — typically 110V AC (LADN22F7) or 240V AC (LADN22U7) for Indian industrial installations, or 220–230V AC (LADN22M7) for European markets.

Q: What is the catalogue number for Schneider auxiliary contactor 2NO+2NC at 415V AC?

The Schneider TeSys D auxiliary contactor with 2NO+2NC contact configuration and 415V AC coil is based on the LADN22 contact block with the N5 coil voltage suffix — resulting in the catalogue number LADN22N5 (415V AC, 50Hz, TeSys D). This is one of the most widely stocked Schneider auxiliary contactor variants at ElectriHub for Indian industrial panel applications where the auxiliary contactor coil is energised directly from the 415V AC control bus without a step-down control transformer. Contact ElectriHub to confirm current stock availability and pricing.

Q: Can I use a Schneider TeSys D auxiliary contactor as an add-on block on a TeSys D main contactor?

The Schneider TeSys D LADN-series auxiliary contactors are standalone DIN-rail devices — not add-on blocks. For expanding the contact count of a TeSys D main contactor (LC1-D series) directly, Schneider produces a separate range of LA1-DN add-on auxiliary contact blocks that clip directly onto the main contactor body. The LADN-series standalone auxiliary contactor is wired separately on the DIN rail and provides an independent coil circuit, whereas the LA1-DN add-on block is mechanically linked to and energised by the main contactor. Contact ElectriHub's technical team to confirm whether you need a standalone LADN auxiliary contactor or an LA1-DN add-on block for your specific panel design.

Q: How do I buy Schneider auxiliary contactor online internationally from ElectriHub?

ElectriHub ships Schneider auxiliary contactors — all LADN contact configurations (1NO+1NC, 2NO+2NC, 3NO+1NC, 3NO+2NC, 4NO, 4NC) and all coil voltages (24VDC through 415V AC) — worldwide, with complete export documentation including commercial invoices, packing lists, certificates of origin, and test certificates where required. Contact our team with the LADN catalogue type and coil voltage suffix, quantity required, and delivery destination for a fast quotation with confirmed lead time. Volume pricing is available for panel builders, MCC manufacturers, OEMs, and large project orders across all Schneider TeSys D and TeSys K auxiliary contactor variants.

Buy Schneider Auxiliary Contactor Online Today

Browse our complete range of Schneider auxiliary contactors above — LADN11 (1NO+1NC), LADN22 (2NO+2NC), LADN31 (3NO+1NC), LADN40 (4NO), 3NO+2NC, and the full TeSys K compact CAD-series range — in every coil voltage from 24VDC to 415V AC. Contact our technical team for contact configuration selection, coil voltage catalogue number confirmation, and TeSys D compatibility guidance for your panel or MCC build. ElectriHub ships 100% genuine Schneider Electric auxiliary contactors worldwide, from a single unit to complete panel builder project volumes. Buy Schneider auxiliary contactor online — 2NO+2NC, 1NO+1NC, 3NO+1NC, 3NO+2NC, 4NO, or any configuration — with fast dispatch, competitive pricing, and full technical support, only at ElectriHub.

Subscribe to our Newsletter