Buy Eaton Auxiliary Contactors Online – DILA & DILER Series, 2NO+2NC, 3NO+1NC & 4NO Configurations
✓ All Contact Configurations In Stock
1NO+1NC, 2NO+2NC, 3NO+1NC, 4NO, 4NC, and mixed-pole special variants — the complete Eaton auxiliary contactor contact configuration range stocked globally at ElectriHub for same or next business day dispatch.
✓ Eaton DILA – Standard Auxiliary Contactor Platform
The Eaton DILA auxiliary contactor is the standard standalone platform for control circuit switching in motor control, automation, and building services panels — available in every NO/NC contact combination, AC and DC coil voltages from 24V to 415V.
✓ Eaton DILER – Compact Auxiliary Contactor Relay
The Eaton DILER auxiliary contactor relay delivers a compact, economy DIN-rail footprint for cost-sensitive and space-constrained OEM panel and machine building applications, available in the most common contact configurations and coil voltages.
✓ 100% Genuine Eaton Products
Every Eaton Auxiliary Contactor supplied by ElectriHub is 100% authentic Eaton (Moeller) product — IEC 60947-5-1 compliant, CE marked — with full manufacturer warranty. No grey-market or counterfeit products across any contact configuration or coil voltage variant.
✓ AC & DC Coil Voltages Available
Eaton auxiliary contactors are stocked at ElectriHub across the full AC coil voltage range (24V, 48V, 110V, 220V/230V, 240V, 380V/400V, 415V) and DC coil voltages (24VDC, 48VDC, 110VDC) — covering control circuit voltage requirements for global panel builds across all markets.
✓ Worldwide Shipping & Technical Support
Fast international dispatch for the full range to Buy Eaton Auxiliary Contactors — with complete export documentation, full shipment tracking, and expert pre-sales support for contact configuration selection, coil voltage confirmation, and DILA/DILER platform selection for your panel build.
Eaton Auxiliary Contactors Type – DILA vs DILER at a Glance
Eaton DILA Auxiliary Contactors
- Full contact configuration range: 1NO+1NC, 2NO+1NC, 2NO+2NC, 3NO+1NC, 1NO+3NC, 4NO, 4NC
- Rated 10A at AC-15 — standard industrial current rating
- Complete coil voltage range: 24V to 415V AC, 24V to 110V DC
- Standard DIN rail footprint
- Default type for industrial, MCC, and infrastructure panels
Eaton DILER Auxiliary Contactor Relays
- Common contact configurations: 2NO+2NC, 3NO+1NC, and selected others
- Compact, economy DIN-rail footprint — narrower than DILA
- Most common coil voltages: 24VDC, 24V AC, 110V AC, 220–240V AC
- Default choice for OEM machine building and cost-sensitive panels
Buy Eaton Auxiliary Contactors by Contact Configuration
Eaton Auxiliary Contactor 1NO+1NC
1 Normally Open + 1 Normally Closed contact. DILA-10(...) — the most compact and cost-efficient standard configuration. Used for single interlock and status signalling duties.
Eaton 2NO+2NC Auxiliary Contactors
2 Normally Open + 2 Normally Closed contacts. DILA-22(...) — the most widely specified balanced configuration for motor starter interlock, auxiliary signalling, and PLC feedback circuits.
Eaton 3NO+1NC Auxiliary Contactors
3 Normally Open + 1 Normally Closed contact. DILA-31(...) — widely used where multiple parallel signal paths and one interlock or safety NC contact are required in one device.
Eaton 4NO Auxiliary Contactors
4 Normally Open contacts. DILA-40(...) — the all-NO configuration for applications requiring maximum parallel make contacts for multi-circuit simultaneous energisation or signalling.
Eaton 4NC Auxiliary Contactor
4 Normally Closed contacts. DILA-04(...) — all-NC configuration for safety interlock, de-energisation signalling, and fail-safe control applications requiring maximum break contacts.
Eaton DILER Auxiliary Contactor 2NO+2NC
Compact economy version of the 2NO+2NC configuration on the DILER platform — for OEM machine panels and cost-sensitive builds where the full DILA specification is not required.
Eaton Auxiliary Contactor 2NO+1NC
2 Normally Open + 1 Normally Closed contact. DILA-21(...) — compact 3-pole configuration used where two NO signal paths and one NC interlock are required in a compact form factor.
Buy Eaton Auxiliary Contactors Online by Series
Eaton DILER – Compact Auxiliary Contactor Relay (2NO+2NC & More)
View Products
Eaton Auxiliary Contactor – Contact Configuration & Catalogue Number Guide
| Contact Configuration | DILA Catalogue Ref. | NO Contacts | NC Contacts | Total Poles | Typical Application |
|---|---|---|---|---|---|
| 1NO + 1NC | DILA-10 | 1 | 1 | 2 | Single interlock and auxiliary signalling — the most compact and economical Eaton auxiliary contactor; used for single-pole make and break control circuit duties in simple motor starters and signalling circuits |
| 2NO + 1NC | DILA-21 | 2 | 1 | 3 | Two parallel make contacts for auxiliary signalling or circuit energisation alongside one normally closed interlock contact; compact 3-pole configuration for intermediate-complexity motor starter auxiliary circuits |
| 2NO + 2NC | DILA-22 | 2 | 2 | 4 | The most widely specified Eaton auxiliary contactor configuration — balanced 4-pole 2NO+2NC for motor starter interlocking, PLC feedback, reversing starter interlock, and general control circuit switching duties |
| 3NO + 1NC | DILA-31 | 3 | 1 | 4 | Three normally open contacts for multiple simultaneous circuit energisation or signalling paths, plus one normally closed contact for interlock or safety signalling; widely used in star-delta starter auxiliary circuits, multi-output PLC interface circuits, and automation panels requiring multiple simultaneous make paths |
| 1NO + 3NC | DILA-13 | 1 | 3 | 4 | Three normally closed contacts for dominant NC interlock, safety, or de-energisation signalling applications with a single make contact for auxiliary indication; used in safety relay interface panels, process interlocking, and emergency shutdown signal routing |
| 4NO | DILA-40 | 4 | 0 | 4 | All normally open — four simultaneous make contacts for maximum parallel circuit energisation; used in multi-circuit lighting control, parallel output PLC interface, multiple pilot lamp energisation, and any application requiring maximum NO contacts in one auxiliary contactor device |
| 4NC | DILA-04 | 0 | 4 | 4 | All normally closed — four simultaneous break contacts for safety interlock, fail-safe de-energisation, and emergency stop signal routing; used in safety relay cascading, process safety shutdown panels, and applications requiring the maximum number of NC contacts in a single auxiliary contactor |
| DILER – 2NO+2NC | DILER-22 | 2 | 2 | 4 | Compact auxiliary contactor relay for cost-sensitive OEM panel, machine building, and small motor control applications where the standard DILA footprint is not required; available in AC and DC coil voltages including 24VDC for PLC-driven control circuits |
Catalogue references shown are indicative Eaton DILA and DILER base type numbers. Full catalogue numbers include a coil voltage suffix — for example, DILA-22 with 230V AC coil or DILA-22 with 24V DC coil carry different suffix codes. Contact ElectriHub's technical team to confirm the exact catalogue number for your required contact configuration and coil voltage.
Eaton DILA vs DILER – Choosing the Right Auxiliary Contactor Platform
| Feature | Eaton DILA Auxiliary Contactor | Eaton DILER Auxiliary Contactor Relay |
|---|---|---|
| Platform Type | Eaton's standard standalone auxiliary contactor — the default choice for the majority of industrial control circuit switching applications | Eaton's compact, cost-engineered auxiliary contactor relay — a smaller DIN-rail footprint for OEM machine panel and small motor control applications |
| Contact Configurations Available | Full range: 1NO+1NC, 2NO+1NC, 2NO+2NC, 3NO+1NC, 1NO+3NC, 4NO, 4NC | Most common configurations: 2NO+2NC, 3NO+1NC, and selected others — a narrower range than DILA |
| Rated Current (AC-15) | 10A at AC-15 (230V) — suitable for the vast majority of control circuit switching duties | Generally similar or slightly lower current rating depending on configuration — adequate for OEM machine panel switching duties |
| Coil Voltage Range | Full coil voltage range: 24V to 415V AC and 24V to 110V DC | Most common variants available in 24VDC, 24V AC, 110V AC, 220–240V AC |
| DIN Rail Footprint | Standard DIN rail auxiliary contactor footprint | Compact footprint — well-suited to space-constrained OEM machine and small panel applications |
| Typical Use Case | Motor starter panels, MCC auxiliary circuits, reversing starter interlocking, PLC interface, building services motor control, infrastructure electrical rooms | High-volume, cost-sensitive OEM machine panel builds and small motor control applications where a compact footprint is sufficient and unit cost is the primary driver |
Eaton Auxiliary Contactor Applications
Motor Starter Interlocking (Reversing Starters)
The Eaton 2NO+2NC auxiliary contactor (DILA-22) is the standard device for electrical interlocking in reversing motor starters — with one 2NO+2NC auxiliary contactor in the forward contactor circuit and one in the reverse contactor circuit, the NC contacts prevent simultaneous energisation of both contactors, eliminating phase-to-phase short circuits across the reversing pair.
PLC Digital Output Interface
Eaton auxiliary contactors with 24VDC coil are the standard interface device between PLC transistor digital outputs and higher-voltage/higher-current control circuits — the 24VDC coil is directly switchable by PLC transistor output cards (NPN/PNP), protecting the PLC output from inductive loads and isolating the control voltage level from the field circuit.
Star-Delta Starter Auxiliary Circuits
The Eaton 3NO+1NC auxiliary contactor (DILA-31) is frequently used in star-delta starter auxiliary control circuits — where multiple simultaneous make contacts are required to energise the timer relay, pilot lamps, and remote status outputs simultaneously with a single NC interlock contact for safety or feedback signalling.
MCC Auxiliary Control & Status Signalling
Eaton DILA-22 (2NO+2NC) auxiliary contactors are the standard signalling device in MCC (Motor Control Centre) outgoing feeder auxiliary circuits — providing local/remote status indication, run/fault feedback to SCADA, and interlock between manual local and remote automatic control modes in industrial process plant MCCs.
Safety Interlock Circuits
The Eaton 4NC auxiliary contactor (DILA-04) and 1NO+3NC variants are specified in machine safety interlock circuits, emergency stop relay cascading, and process safety shutdown panels where the maximum number of normally closed break contacts in a single device is required for fail-safe de-energisation signal routing.
Multi-Circuit Lighting & Heating Control
The Eaton 4NO auxiliary contactor (DILA-40) provides four simultaneous make contacts for multi-circuit lighting, heating, or auxiliary load switching applications — where a single coil energisation must simultaneously energise up to four independent load circuits, pilot lamps, or downstream relay coils.
OEM Machine & Packaging Panels (DILER)
The Eaton DILER auxiliary contactor is widely used in OEM machine tool, packaging, and textile machine control panels where a compact DIN-rail footprint and lower unit cost are the priority over the full DILA contact configuration range.
Building Management System (BMS) Interface
Eaton DILA auxiliary contactors — typically DILA-22 (2NO+2NC) with 24VDC or 230V AC coils — are a standard BMS-to-field interface device for building services motor control: fan coil units, AHU starters, chiller auxiliaries, and HVAC motor run/status signalling in commercial building electrical rooms and BMS control panels.
Remote Run/Stop Control of Motor Starters
An Eaton auxiliary contactor wired as a latching (self-holding) relay circuit — using a NO contact in series with the start pushbutton to maintain the coil circuit after the start button is released — is the classic motor starter remote run/stop control circuit used across decades of industrial motor starter panel designs.
Alarm & Fault Annunciation Panels
Eaton DILA-22 and DILA-31 auxiliary contactors relay fault, trip, and alarm signals from motor protection relays, MPCB trip contacts, and overload relay auxiliary contacts to annunciator panels, SCADA digital inputs, and remote alarm systems — providing the voltage isolation and contact multiplication required between the protection device output and the monitoring system input.
Timer & Counter Relay Coil Switching
Eaton auxiliary contactors switch timer relay and counter relay coil circuits in sequential automation control — where PLC outputs or mechanical pushbuttons at low current capacity are used to drive higher-current coil loads via the Eaton DILA or DILER auxiliary contactor as the intermediate switching device.
Contact Us
Need help selecting the right Eaton Auxiliary Contactor — contact configuration (2NO+2NC, 1NO+1NC, 3NO+1NC, 4NO, or others), DILA or DILER platform, and coil voltage? Our technical team is ready to assist.
Contact NowDownload Our Product Line Card
Get a detailed overview of our complete product range with specifications and key features across all brands and product families we supply worldwide, including the full Eaton DILA and DILER auxiliary contactor range.
Download Line CardCheck Our Company Profile
Learn more about ElectriHub — our company profile, global capabilities, and the full range of Eaton control and protection products we supply worldwide for industrial, OEM, and infrastructure projects.
Download ProfileBuy Eaton Auxiliary Contactors Online – Complete DILA & DILER Range Overview
When you Buy Eaton Auxiliary Contactors online from ElectriHub, you gain access to the complete Eaton auxiliary contactor range — every standard contact configuration and coil voltage in one catalogue. Eaton's DILA-series auxiliary contactor is the standard for control circuit switching in motor starter panels, MCCs, automation cabinets, and building services electrical rooms worldwide — available in 1NO+1NC, 2NO+1NC, Eaton 2NO+2NC auxiliary contactors (DILA-22), Eaton 3NO+1NC auxiliary contactors (DILA-31), 1NO+3NC, and Eaton 4NO auxiliary contactors (DILA-40), plus 4NC (DILA-04). The compact Eaton DILER auxiliary contactor relay extends the range to cost-sensitive OEM machine panel applications. Coil voltages span the full global range: 24VDC, 24V AC, 48V AC, 110V AC, 110VDC, 220–230V AC, 240V AC, 380–400V AC, and 415V AC — covering every control circuit voltage requirement for Indian and international panel builds. Every Eaton Auxiliary Contactor supplied by ElectriHub is IEC 60947-5-1 compliant, CE marked, and available globally with full technical support and worldwide shipping.
Eaton 2NO+2NC Auxiliary Contactors – DILA-22 Deep Dive
The Eaton 2NO+2NC auxiliary contactor — catalogue type DILA-22 — is the most widely specified Eaton auxiliary contactor configuration globally. With two normally open (NO) contacts for circuit make and two normally closed (NC) contacts for interlock and break duties, the DILA-22 provides the balanced 4-pole configuration required for the vast majority of motor starter interlock, PLC feedback, reversing starter electrical interlock, SCADA status signalling, and auxiliary circuit switching applications in industrial and building services panels. It is available in every standard coil voltage — from 24VDC for PLC-driven control circuits to 415V AC for Indian panel applications without a step-down control transformer — with all voltage variants stocked at ElectriHub for same or next business day dispatch.
Eaton 3NO+1NC Auxiliary Contactors – DILA-31
The Eaton 3NO+1NC auxiliary contactor (DILA-31) provides three normally open contacts for simultaneous multiple-circuit energisation alongside one normally closed contact for interlock or safety signalling — the standard choice for star-delta starter auxiliary circuits, multi-output PLC interface panels, and automation applications requiring multiple simultaneous NO outputs with a single NC interlock. It is available in the same full coil voltage range as the DILA-22, and ElectriHub stocks the most common coil voltages for same or next business day dispatch.
Eaton 4NO Auxiliary Contactors – DILA-40
The Eaton 4NO auxiliary contactor (DILA-40) provides four normally open contacts for maximum simultaneous make capability — the all-NO configuration for multi-circuit lighting control, parallel load energisation, multiple pilot lamp switching, and any application where the maximum number of normally open contacts in a single auxiliary contactor device is required. It is available in the same coil voltage range as other Eaton DILA-series auxiliary contactors — contact ElectriHub for stock confirmation and coil voltage options.
Eaton DILA Auxiliary Contactors – Platform Overview
Eaton DILA auxiliary contactors are Eaton's standard standalone auxiliary contactor platform, engineered for reliable long-term operation in motor starter panels, MCCs, and automation cabinets. The DILA series covers the full spectrum of contact configurations — from compact 1NO+1NC units through to all-NO or all-NC 4-pole devices — with a 10A rated current at AC-15 suitable for the vast majority of control circuit, PLC input card, and pilot lamp switching duties. DILA auxiliary contactors are IEC 60947-5-1 compliant and CE marked, and ElectriHub stocks the complete range across all standard coil voltages for immediate dispatch.
Eaton DILER Auxiliary Contactors – Compact Platform Overview
Eaton DILER auxiliary contactors are Eaton's compact, cost-engineered auxiliary contactor relay platform — designed for OEM machine building and space- or cost-constrained applications where the full DILA specification is not required. Available in the most common contact configurations (principally 2NO+2NC and 3NO+1NC) and the most widely used coil voltages (24VDC, 24V AC, 110V AC, 220–240V AC), the DILER series occupies a narrower DIN-rail footprint than DILA, making it the preferred choice for high-volume, cost-sensitive OEM panel builds.
How to Select the Right Eaton Auxiliary Contactor – Step-by-Step
- Determine the Required Contact Configuration: Count the number of normally open (NO) and normally closed (NC) contacts required for your circuit — interlock contacts are typically NC, signal and energisation contacts are typically NO. Select the DILA configuration that best matches: DILA-10 (1NO+1NC), DILA-22 (2NO+2NC), DILA-31 (3NO+1NC), DILA-40 (4NO), or DILA-04 (4NC).
- Choose DILA or DILER: Select DILA for the full configuration range, standard current rating, and widest coil voltage coverage. Select DILER only where a compact footprint and lower unit cost are the primary drivers and a standard configuration is sufficient.
- Select Coil Voltage: Identify the control circuit voltage of your panel — 24VDC (most common for PLC panels), 24V AC, 110V AC, 220–230V AC, 240V AC, or 415V AC for Indian panels.
- Confirm Contact Current Rating: Eaton auxiliary contactors are rated around 10A at AC-15 (230V) — adequate for the vast majority of control circuit coil, lamp, and PLC input card loads. For higher current switching duties in the control circuit, consult ElectriHub's technical team for the correct device.
- Check AC or DC Coil: DC coils (24VDC, 48VDC, 110VDC) are recommended for PLC-driven applications — no inrush current, faster operate/release times, and direct PLC transistor output compatibility.
- Specify Quantity and Delivery: Contact ElectriHub with the DILA/DILER catalogue type, coil voltage suffix, quantity, and delivery destination for a fast quotation — volume pricing available for panel builders, MCC manufacturers, OEMs, and EPC contractors.
Why Buy Eaton Auxiliary Contactors from ElectriHub?
- ✓ Complete Eaton DILA and DILER auxiliary contactor range — all contact configurations (1NO+1NC, 2NO+2NC, 3NO+1NC, 4NO, 4NC, and more) stocked globally at ElectriHub
- ✓ All coil voltages in stock — 24VDC through 415V AC — covering every global control circuit voltage requirement for Indian, European, Middle Eastern, and international panel builds
- ✓ 100% genuine Eaton (Moeller) products — IEC 60947-5-1 compliant, CE marked — with full manufacturer warranty on every unit supplied
- ✓ Technical support for contact configuration selection, DILA vs DILER platform selection, and coil voltage confirmation
- ✓ Competitive pricing with volume discounts for OEMs, panel builders, MCC manufacturers, EPC contractors, and large project orders across all Eaton auxiliary contactor configurations
- ✓ Worldwide shipping with full tracking and export documentation — urgent orders dispatched same or next business day for standard stocked Eaton auxiliary contactor variants
Frequently Asked Questions – Buy Eaton Auxiliary Contactors Online
Q: What is the difference between Eaton DILA and Eaton DILER auxiliary contactors?
Eaton DILA auxiliary contactors are the standard standalone platform, offering the widest contact configuration range and full coil voltage coverage — the default choice for industrial motor control, MCC, and infrastructure panels. Eaton DILER auxiliary contactors are a compact, cost-engineered auxiliary contactor relay with a narrower DIN-rail footprint and a more limited contact configuration range, suited to OEM machine building and cost-sensitive panel applications. Both platforms are IEC 60947-5-1 compliant and CE marked.
Q: What does Eaton 2NO+2NC mean in an auxiliary contactor?
In an Eaton 2NO+2NC auxiliary contactor (DILA-22), the contact configuration means the device has 2 Normally Open (NO) contacts and 2 Normally Closed (NC) contacts — 4 poles total. When the coil is de-energised (off), the 2 NO contacts are open (circuit broken) and the 2 NC contacts are closed (circuit made). When the coil is energised (on), the 2 NO contacts close (circuit made) and the 2 NC contacts open (circuit broken). This balanced 4-pole configuration enables simultaneous circuit energisation (via NO contacts) and interlock or signalling (via NC contacts) in a single device.
Q: Which Eaton auxiliary contactor coil voltage should I use for a PLC-controlled panel?
For a PLC-driven control panel, the recommended Eaton auxiliary contactor coil voltage is 24VDC. The 24VDC coil is directly switchable by PLC transistor digital output cards (NPN or PNP), with no AC inrush current surge, faster operate and release times than AC coils, and simple wiring from the 24VDC auxiliary power supply typically available in any PLC control panel. For panels without a PLC and with an AC control bus, select the coil voltage matching your control transformer secondary — typically 110V AC or 240V AC for Indian industrial installations, or 220–230V AC for European markets.
Q: What is the Eaton DILA auxiliary contactor?
The Eaton DILA is Eaton's (formerly Moeller's) standard auxiliary contactor product family, providing the full spectrum of NO NC configurations from compact 1NO+1NC through to 4NO/4NC, and the full coil voltage range for control circuit switching alongside Eaton's main contactor range. Contact ElectriHub to confirm the exact DILA catalogue reference for your required configuration and coil voltage.
Q: What is the Eaton DILER auxiliary contactor?
The Eaton DILER is Eaton's compact auxiliary contactor relay family, designed as a cost-effective, space-saving alternative to the DILA series for OEM machine panel and small motor control applications. DILER is available in the most common configurations (2NO+2NC, 3NO+1NC) and coil voltages, and is a standalone DIN-rail device.
Q: How do I buy Eaton Auxiliary Contactors online internationally from ElectriHub?
ElectriHub ships Eaton Auxiliary Contactors — all DILA and DILER contact configurations (1NO+1NC, 2NO+2NC, 3NO+1NC, 4NO, 4NC) and all coil voltages (24VDC through 415V AC) — worldwide, with complete export documentation including commercial invoices, packing lists, certificates of origin, and test certificates where required. Contact our team with the DILA or DILER catalogue type and coil voltage suffix, quantity required, and delivery destination for a fast quotation with confirmed lead time. Volume pricing is available for panel builders, MCC manufacturers, OEMs, and large project orders across all Eaton auxiliary contactor variants.
Buy Eaton Auxiliary Contactors Online Today
Browse our complete range of Eaton Auxiliary Contactors above — Eaton 2NO+2NC auxiliary contactors (DILA-22), Eaton 3NO+1NC auxiliary contactors (DILA-31), Eaton 4NO auxiliary contactors (DILA-40), 4NC (DILA-04), and the full Eaton DILER compact range — in every coil voltage from 24VDC to 415V AC. Contact our technical team for contact configuration selection, DILA vs DILER platform guidance, and coil voltage confirmation for your panel or MCC build. ElectriHub ships 100% genuine Eaton auxiliary contactors worldwide, from a single unit to complete panel builder project volumes. Buy Eaton Auxiliary Contactors online — 2NO+2NC, 1NO+1NC, 3NO+1NC, 4NO, DILA, or DILER — with fast dispatch, competitive pricing, and full technical support, only at ElectriHub.
Connectors
Electrical Conduits and Fittings
EV Chargers
Home Automation
Mixed Products
Power Supplies and Tools
Rack Power Distribution
Low Voltage Breakers
Contactors and Contactor Relays
Home Distribution Products
Power Monitoring & PF Correction
Changeover Switches & Isolators
Industrial Automation Products
Signalling and Controlling
Medium Voltage Products
Wires & Cables
Industrial Motors
Pumps