L&T VFD – Variable Frequency Drive Online | Sx2000, Hx2000, Cx2000, Fx2000 | ElectriHub

L&T VFD – Variable Frequency Drive | Buy L&T VFD Online

ElectriHub is your authorised source to Buy L&T VFD Online — the complete range of L&T (Larsen & Toubro) Variable Frequency Drives from the L&T Electrical & Automation x2000 series. Our range covers the L&T Cx2000 compact drive (0.1kW–11kW), the L&T Sx2000 smart series (0.75kW–90kW), the L&T Fx2000 flexi series for heavy-duty and high-performance applications (0.75kW–450kW), and the L&T Hx2000 HVAC-optimised drive (5.5kW–90kW). Every L&T VFD is built for reliable speed and torque control of three-phase induction motors, with V/F control, sensorless vector control, built-in PID, RS485 Modbus communication, and application presets for pumps, fans, conveyors, compressors, cranes, elevators, textile machinery, and process equipment. Trusted across Indian and global industry for its rugged build and low cost of ownership — buy genuine L&T VFD online with worldwide shipping, competitive pricing, and expert technical support, only at ElectriHub.

✓ Complete L&T VFD Range

Cx2000, Sx2000, Fx2000, and Hx2000 series — single-phase and three-phase, 230V and 415V, 0.1kW to 450kW — with all keypads, communication cards, braking units, and spare parts stocked and available worldwide.

✓ Buy L&T VFD Online, Fast

Simple online ordering by model, kW rating, or part number — with instant quotation, same or next business day dispatch on standard L&T VFD ratings, and full order tracking.

✓ 100% Genuine Products

Authentic L&T Electrical & Automation Variable Frequency Drives sourced through authorised channels, with full manufacturer warranty on every L&T VFD supplied by ElectriHub.

✓ 0.1kW to 450kW Coverage

From the compact Cx2000 for small motor loads to the Fx2000 flexi series for 450kW heavy-duty applications — the widest L&T VFD power range under one roof, with HD and ND rating options.

✓ Worldwide Shipping

Fast international dispatch with complete export documentation, full shipment tracking, and urgent fulfilment for all standard L&T VFD models and accessories.

✓ Technical Support

Expert pre-sales engineering support for L&T VFD series selection, kW and current rating sizing, HD vs ND duty selection, keypad and communication accessory specification, and retrofit guidance.

0.1–450kW Power Rating Range
Cx/Sx/Fx/Hx 2000 Series
230V / 415V Single & Three Phase
0–400Hz Max Output Frequency
IP20 / IP66 Enclosure Ratings Available
V/F & SVC Control Modes

Shop L&T VFD by Series

L&T Sx2000 VFD Smart Series Variable Frequency Drive 0.75kW to 90kW
Sx2000 – 0.75kW to 90kW

L&T Sx2000 VFD – Smart Series

View Products
L&T Cx2000 VFD Compact Series Variable Frequency Drive 0.1kW to 11kW
Cx2000 – 0.1kW to 11kW

L&T Cx2000 VFD – Compact Series

View Products
L&T Fx2000 VFD Flexi Series Variable Frequency Drive 0.75kW to 450kW
Fx2000 – 0.75kW to 450kW

L&T Fx2000 VFD – Flexi Series

View Products
L&T Hx2000 VFD HVAC Series Variable Frequency Drive 5.5kW to 90kW
Hx2000 – 5.5kW to 90kW

L&T Hx2000 VFD – HVAC Series

View Products
L&T VFD Accessories Keypad Braking Unit Communication Card
Accessories & Spare Parts

L&T VFD Accessories – Keypads, Braking Units, Comms Cards

View Products

L&T VFD – Series Selection Guide

Series Power Range Supply Voltage Control Type Key Features Best Suited For
Cx2000 0.1kW – 11kW 1-Phase 230V / 3-Phase 230V & 415V V/F Control Compact & lightweight, built-in PID, 2nd motor operation, tool-less fan replacement, built-in brake chopper Conveyors, small pumps, fans, textile machinery, motor starter replacement
Sx2000 0.75kW – 90kW 1-Phase 230V / 3-Phase 230V & 415V, IP66 option V/F & Sensorless Vector Control 200% starting torque at 0.5Hz, master–slave RS485 operation, LCD keypad, built-in PLC function, IP66 outdoor variant Compressors, conveyors, machine tools, elevators, plastic extruders, wire drawing, submersible pumps
Fx2000 0.75kW – 450kW 3-Phase 415V V/F, V/F with PG, Slip Compensation, Sensorless & Closed-Loop Vector Control Highest power range in the L&T VFD family, precision closed-loop control, heavy-duty (HD) and normal-duty (ND) ratings Cranes, plastic winders, high-speed elevators, cement kilns, crushers, heavy process machinery
Hx2000 5.5kW – 90kW 3-Phase 415V V/F Control, Energy-Optimised Built-in EMC filter, multi-motor control (1 main + 5 auxiliary), RTC scheduling, Fire Mode for smoke exhaust/pressurisation fans HVAC systems, chillers, cooling towers, building fans & pumps, fire mode ventilation

L&T VFD Applications Across Industries

Pumps & Submersible Pumps

L&T Sx2000 and Cx2000 provide soft-start speed control for centrifugal and submersible pumps in water supply, agriculture, and process plants — reducing water hammer and energy consumption at part load.

HVAC – Fans & Chillers

L&T Hx2000 is purpose-built for HVAC fans, cooling towers, and chiller pumps in commercial buildings, with multi-motor control and Fire Mode for smoke exhaust and stairwell pressurisation fans during emergencies.

Conveyors & Material Handling

L&T Cx2000 and Sx2000 give precise speed and torque control on conveyor belts and material handling lines, with built-in PID and multi-function I/O for integration with PLC-based control systems.

Compressors

L&T Sx2000's high starting torque and sensorless vector control suit screw and reciprocating compressor loads, enabling smooth ramp-up and reduced mechanical stress compared to direct-on-line starting.

Cranes, Hoists & Elevators

L&T Fx2000 with closed-loop vector control and V/F-PG mode delivers the precise torque and positioning control required for cranes, hoists, and high-speed elevators.

Textile Machinery

L&T Cx2000 and Sx2000 are widely used on textile spinning, winding, and processing machinery, where consistent speed regulation and multi-motor synchronisation are essential.

Cement, Crushers & Heavy Process Plant

L&T Fx2000 up to 450kW handles the high starting torque and continuous heavy-duty loads found in cement kilns, crushers, and large process machinery.

Plastic Extruders & Wire Drawing

L&T Sx2000 and Fx2000 provide the fine speed control needed for plastic extrusion lines and wire drawing machines, where line-speed consistency directly affects product quality.

Motor Starter Replacement

L&T Cx2000 is commonly used as a direct, cost-effective replacement for conventional star-delta and DOL motor starters — adding soft-start, energy saving, and motor protection features with communication compatibility.

Contact Us

Have questions or need assistance choosing the right L&T VFD? Reach out to our team for expert help and product support.

Contact Now

Download Our Product Line Card

Get a detailed overview of our L&T VFD range with specifications and key features.

Download Line Card

Check Our Company Profile

Learn more about ElectriHub

Download Profile

What is an L&T VFD?

An L&T VFD (Variable Frequency Drive), also known as an AC drive or inverter, is an electronic motor controller manufactured by L&T Electrical & Automation that varies the frequency and voltage supplied to a three-phase induction motor to precisely control its speed and torque. Instead of running a motor at fixed line frequency and switching it directly on or off, an L&T VFD ramps the motor up and down smoothly, matches motor speed to actual process demand, and can reduce energy consumption significantly on variable-torque loads such as pumps and fans. L&T's x2000 series — comprising the Cx2000, Sx2000, Fx2000, and Hx2000 — covers power ratings from 0.1kW to 450kW across single-phase 230V and three-phase 230V/415V supplies, with common features including V/F and sensorless vector control, built-in PID, RS485 Modbus communication, application presets, and a shared LCD/LED keypad (DOP-200) family across models. Customers looking to buy L&T VFD online can choose the series that matches their motor power, duty cycle, and application from ElectriHub's complete stocked range.

L&T VFD Series Explained – Cx2000 vs Sx2000 vs Fx2000 vs Hx2000

L&T's Cx2000 is the compact, entry-level VFD series — covering 0.1kW to 11kW — designed as a direct, cost-effective replacement for conventional motor starters on conveyors, small pumps, fans, and textile machinery, with built-in PID and 2nd-motor operation letting one drive serve two different loads. The Sx2000 smart series extends coverage from 0.75kW up to 90kW and adds sensorless vector control with 200% starting torque at 0.5Hz for demanding low-speed applications such as compressors, machine tools, elevators, and plastic extruders; it is also available in an IP66 outdoor-rated enclosure and supports master–slave RS485 operation across multiple drives. The Fx2000 flexi series is L&T's high-performance, heavy-duty drive — covering 0.75kW to 450kW with V/F-PG, slip compensation, and closed-loop vector control — built for the toughest applications: cranes, plastic winders, high-speed elevators, cement kilns, and crushers. The Hx2000 is purpose-optimised for HVAC duty — 5.5kW to 90kW — with a built-in EMC filter, multi-motor control for up to five auxiliary motors, real-time-clock (RTC) scheduling for building operating hours, and a dedicated Fire Mode that keeps smoke exhaust and pressurisation fans running during a fire event even if a fault is detected.

Key Features Common Across L&T x2000 VFD Series

Across the Cx2000, Sx2000, Fx2000, and Hx2000 ranges, L&T VFDs share a common platform of features: a three-phase input voltage range of 380–480V (-15%/+10%) for the 415V models; maximum output frequency up to 400Hz (up to 120Hz in sensorless vector mode); a built-in 24V control power source; application-specific presets for general industrial, pump, fan, and HVAC duty; conformal coating on control boards to IEC 60721-3-3 class 3C2 for humid and dusty environments common in Indian industrial sites; an operating ambient range of -10°C to 50°C; and on-board storage of up to five fault event histories for troubleshooting. Overload capacity is rated at 150% of rated current for 60 seconds in heavy-duty (HD) mode and 110% for 60 seconds in normal-duty (ND) mode, letting the same drive be sized for either constant-torque or variable-torque loads depending on the application.

How to Select the Right L&T VFD – Step-by-Step

  1. Determine Motor Power and Duty: Match the motor's rated kW/HP to the drive's HD (heavy duty, constant torque) or ND (normal duty, variable torque) rating — HD ratings are lower current for the same frame and suit loads like conveyors and compressors, while ND ratings suit pumps and fans.
  2. Choose Supply Voltage and Phase: Confirm whether the installation is single-phase 230V or three-phase 230V/415V — Cx2000 and Sx2000 offer single-phase options for smaller motors, while Fx2000 and Hx2000 are three-phase 415V only.
  3. Select the Series by Application: Cx2000 for basic motor starter replacement and small loads; Sx2000 for general-purpose applications needing higher starting torque or IP66 protection; Fx2000 for heavy-duty, high-precision, or high-power (up to 450kW) applications; Hx2000 for HVAC fans, pumps, and fire-mode ventilation duty.
  4. Check Control Mode Requirements: V/F control is sufficient for simple pump and fan loads; sensorless or closed-loop vector control (Sx2000/Fx2000) is required where high starting torque, precise speed regulation, or positioning accuracy is needed.
  5. Plan Communication and Multi-Drive Needs: Specify RS485 Modbus communication cards for BMS/SCADA integration, and consider Sx2000 master–slave wiring or Hx2000 multi-motor control where several motors must be coordinated from one controller.
  6. Select Accessories: LCD/LED keypad (DOP-200 family), external braking unit and resistor for high-inertia decelerating loads, EMC/RFI filters for electrically noisy environments, and DC/AC line reactors for harmonic mitigation on larger drives.

Why Buy L&T VFD Online from ElectriHub?

  • ✓ Complete L&T VFD range — Cx2000 (0.1kW–11kW), Sx2000 (0.75kW–90kW), Fx2000 (0.75kW–450kW), Hx2000 (5.5kW–90kW) — single-phase and three-phase, IP20 and IP66
  • ✓ 100% genuine L&T Electrical & Automation products with full manufacturer warranty
  • ✓ All keypad, communication, braking, and filter accessories stocked alongside the drives
  • ✓ Competitive pricing with volume discounts for OEMs, panel builders, and project orders
  • ✓ Worldwide shipping with full tracking and export documentation — urgent orders dispatched same or next business day
  • ✓ Technical pre-sales support for series selection, HD/ND sizing, control mode selection, and multi-drive/communication architecture
  • ✓ Replacement and retrofit support for upgrading conventional motor starters or older drives to the current L&T x2000 platform

Frequently Asked Questions – L&T VFD

Q: Which L&T VFD series should I choose for a water pump?

For general water pumping applications, the L&T Sx2000 or Cx2000 are the most commonly specified series. The Cx2000 suits smaller pumps up to 11kW where basic V/F control and energy saving are the goal, while the Sx2000 — available up to 90kW and in an IP66 outdoor-rated enclosure — is better suited to larger or submersible pump installations, offering higher starting torque and built-in PID for pressure or flow control loops.

Q: What is the difference between HD and ND rating on an L&T VFD?

HD (Heavy Duty) rating provides a higher overload capacity — typically 150% of rated current for 60 seconds — suited to constant-torque loads such as conveyors, compressors, and cranes that need extra torque during starting or momentary overload. ND (Normal Duty) rating provides a lower overload capacity — typically 110% of rated current for 60 seconds — but a higher continuous current rating, and suits variable-torque loads such as pumps and fans where torque demand falls off at lower speed. The same L&T VFD frame is often rated for both a lower HD kW and a higher ND kW.

Q: Can one L&T VFD control multiple motors?

Yes. The L&T Hx2000 supports multiple-motor control of one main motor plus up to five auxiliary motors, commonly used for staged control of multiple pumps or fans in HVAC systems. The L&T Sx2000 also supports master–slave operation over RS485, allowing several Sx2000 drives to run in a coordinated group. For applications needing independent, simultaneous full-speed control of multiple motors, a separate VFD per motor is still the standard recommendation.

Q: What is Fire Mode on the L&T Hx2000?

Fire Mode on the L&T Hx2000 is a safety override function for smoke exhaust and stairwell pressurisation fans. When activated — typically by a signal from the building fire alarm system — the Hx2000 keeps the connected fan motor running at the commanded speed even if the drive detects a fault condition that would normally trip it, helping maintain smoke extraction and safe evacuation routes during a fire event.

Q: Can I order L&T VFDs internationally from ElectriHub?

Yes. ElectriHub ships L&T VFDs worldwide — Cx2000, Sx2000, Fx2000, and Hx2000 series, all standard kW ratings, single-phase and three-phase — with complete export documentation including commercial invoices, packing lists, and certificates of origin. Contact our team with your required model, kW rating, and delivery destination for a fast quotation and lead time confirmation.

Buy L&T VFD Online Today

Browse our complete range of L&T Variable Frequency Drives above — Cx2000 (0.1kW–11kW), Sx2000 (0.75kW–90kW), Fx2000 (0.75kW–450kW), and Hx2000 (5.5kW–90kW) — with full keypad, communication, and braking accessories, or contact our technical team for series selection, HD/ND sizing, and multi-drive architecture guidance. ElectriHub ships genuine L&T VFDs worldwide and supports projects of all sizes, from a single replacement drive to complete panel-builder orders. Buy L&T VFD online with fast dispatch, competitive pricing, and full technical support — only at ElectriHub.

Subscribe to our Newsletter